Bosch Appliances D9412GV2 Video Game Controller User Manual


 
D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 60
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
2.11.2 Keypad Selections
The D9000GV2 control panel series uses
Programming choices in this section determine if
keypad functions are disabled (blank), enabled (E), or
passcode (P) restricted.
separate keystrokes to program the
custom functions that accurately
represent the two separate user
interfaces, the D1255 and D1260
keypads.
Custom functions written for the D1255
that use the [PREV], [ESC], and [NEXT]
keys do not work on the D1260.
Custom function written for the D1260
that use the softkeys (located on the
sides of the keypad display) do not work
when executed from the D1255 keypad.
Press the [SPACE] bar to scroll through the
selections. Press [ENTER] when the correct selection
appears in the display.
Table 27: Keypad Programming Choices
Selection Description
Blank
Disable the function panel-wide.
The keypad shows NO
AUTHORITY if you access the
2.11 User Interface
function using a command or the
Function List.
Define which functions can be used by each of the
fourteen user authority levels. Each user can be
assigned the same or different authority level by area.
The user has rights in the area where the keypad is
assigned, based on the authority level assigned to the
user’s pass code for that area.
E
Enable the function panel-wide.
The function can be executed
without entering a pass code.
P
Pass code required. When the
pass code is entered at the
keypad, the control panel checks
When the pass code is entered at the keypad, the
control panel checks the authority level. The control
panel executes the function only in areas where the
pass code has the authority to use the function.
the user’s authority level. Refer to
Section 2.11.4 Authority Level
Selections . on page 67
2.11.1 Commands
Similar to command initiation used in other Bosch
Security Systems, Inc. products, the Commands
method provides continuity in the arming commands
across product lines and makes an easy transition for
dealers using other Bosch Security Systems, Inc.
products. With commands, the end user presses
[COMMAND] and then the numeral of the command
to initiate. For example, [COMMAND][2] arms the
perimeter of the area. Some prompts can be
accessed only from a menu. These prompts are
indicated by (Menu Function only). To access these
functions, press [MENU], enter the function number,
and use the [PREV] and [NEXT] keys to scroll through
the choices.
The D9412GV2/D7412GV2 Program Record Sheet
(P/N: F01U003635) lists the commands available with
the system. Command numbers are shown in the
column labeled Command. If a particular function
does not have a command number, it can be
accessed only through the Function List.
If you plan to use only commands to operate the
system, and to arm and disarm by entering a pass
code, you do not need to program Custom Function
or Function List.
Refer to Section 2.11.4 Authority Level
Selections on page for a detailed 67
description of the functions on the
following pages. These parameters
determine only if the authority level
functions are pass-code protected.