D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 68
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
L## Master Arm Delay L## Perim Delay
Default: Refer to the program record sheet Default: Refer to the program record sheet
Selection
:
Blank or E Selection: Blank or E
Function Name
Function
No.
Alternate
Keystroke
Function Name
Function
No.
Alternate
Keystroke
5
[COMMAND][3]
Perimeter Delay
Arm
2
[COMMAND][1]
Master Arm
Delay
Delay arm all Perimeter Delay point responses only in
the area where the keypad is assigned.
Master arms areas based on the CC# Scope of the
keypad using an exit delay time.
L## Watch Mode
When this item is accessed through the Function List,
Master Arm All allows the user to arm all areas
according to the authority level of the user and within
the CC# Scope of the keypad using an exit delay
time.
Default: Refer to the program record sheet
Selection: Blank or E
Function Name
Function
No.
Alternate
Keystroke
Arm Area arms only the area displayed. If COMMAND
1 is used, it arms only the area where the keypad is
assigned.
6 Watch Mode [COMMAND][6]
Initiate the Watch Mode in the area to which this
keypad is assigned.
L## Mstr Arm Inst
L## Perim Partial
Default: Refer to the program record sheet
Selection: Blank or E
Default: Refer to the program record sheet
Selection: Blank or E
Function Name
Function
No.
Alternate
Keystroke
Function Name
Function
No.
Alternate
Keystroke
3
[COMMAND][1][1]
Master Arm
Instant
7
[COMMAND][8]
Perimeter Partial
Arm
This authority level permission allows a user to
execute the Master Arm Inst function. Refer to
Mstr
Arm Inst
Partially arms only the area where the keypad is
assigned.
on page61.
Arm Area arms only the area to which the keypad is
assigned.
If COMMAND 11 is used, it arms only the area where
the keypad is assigned.
Use COMMAND 11 carefully because all
Perimeter and Interior points become
Instant Armed.
L## Perim Instant
Default: Refer to the program record sheet
Selection: Blank or E
Function
No.
Function Name
Alternate
Keystroke
4
Perimeter Instant
Arm
[COMMAND][2]
Instant arm all Perimeter points, including Delayed
points, only in the area where the keypad is assigned.
This function ignores the A# FA Bypass
Max entry in Area Parameters.
Local Only Reporting: No Closing
Report is sent to the central station, but a
Perimeter Delay Closing Event is
generated in the event log.
L## View Area Stat
Default: Refer to the program record sheet
Selection: Blank or E
Function Name
Function
No.
Alternate
Keystroke
8 View Area Status
(Menu function
only)
View the current arm or disarm status and the not
ready to arm status of all areas within the scope of the
keypad in this area. The user needs arming and