Bosch Appliances D9412GV2 Video Game Controller User Manual


 
D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 35
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
2.8 Miscellaneous
RPS Ph
Duress Type
Default: Blank
Selection:
Blank or up to 24 characters
Default: 0
Blank Control panel does not dial a phone
number for RPS.
Selection:
0, 1, 2, or 3
0 Do not send a duress event with any
passcode.
1 to 24
characters
Enter up to 24 characters to define
dialing characteristics.
1 Increase the last digit by 1 to generate an
alarm. For example, if the passcode is 6123,
6124 activates a duress alarm.
This is the phone number the control panel dials to
contact RPS. The control panel dials the
programmed number on Phone #5 (RPS Ph #) when
any of the following events occur:
If the last digit of the passcode is 0, a duress
alarm occurs when the user enters 1 as the
last digit of the passcode.
Log % Full threshold is achieved.
If Log % Full is programmed with a
value (1 to 99) and an RPS phone
number is programmed, the control
panel dials the RPS phone number
when the log threshold is reached. This
function is not available in RPS. Do not
program Log % Full and an RPS phone
number at the same time.
If the last digit of the passcode is 9, a duress
alarm occurs when the user enters 0 as the
last digit of the passcode.
2 Increase the last digit by 2 to generate an
alarm. For example, if the passcode is 6123,
6125 activates a duress alarm.
If the last digit of the passcode is 8, a duress
alarm occurs when the user enters 0 as the
last digit of the passcode.
The control panel is contacted by RPS and RPS
Call Back is programmed Yes.
If the last digit of the passcode is 9, a duress
alarm occurs when the user enters 1 as the
last digit of the passcode.
The user enters COMMAND 43 and selects the
call RPS option from the menu. On the D1255:
1. Press [COMAND][4][3].
3 Send a Duress event when any Passcode with
L# Send Duress set to Yes is entered.
2. Press [NEXT] until CONTACT RPS?
appears, then press [ENTER].
3. Wait for RPS VIA PHONE? to appear, then
press [ENTER].
This program item determines if users add one (+1)
or two (+2) to the last digit of the passcode. To
activate a duress alarm, the user increases the value
of the last digit of the passcode when entering it at
the keypad.
The control panel tries to contact RPS
only once using this method.
Refer to Section 6.4 SDI RPS Parameters on page
128 for other connection methods.
Refer to Phone 1 in Section 2.1 Phone on
page 11 for descriptions of special
programming values for the RPS Phone
number.
Duress is enabled in Area Parameters by
setting A# Duress Enable to Yes.
The duress alarm activates when a user
enters the duress passcode followed by
the termination keys ([ESC] or [ENT]).
For SIA CP-01 Compliance
Duress Type must be set to 3.