D# Access Granted?
D# Enter Request?
Default: No
Default: No
Selection: Yes or No
Selection: Yes or No
Yes
Access Events from this door
controller are sent to the control
panel for processing.
A Door RTE Event from this door
controller is sent to the control panel
for processing.
Yes
No
Access Events from this door
controller are not sent to the control
panel for processing.
A Door RTE Event from this door
controller is not sent to the control
panel for processing.
No
This program item determines if RTE Events are sent
to the control panel for processing memory, printing,
and remote reporting.
This program item determines if Access Granted and
Door Request Events are sent to the control panel for
processing memory, printing, and remote reporting.
A successful Access Event can be
started by a(n):
Valid user ID
Valid door state changed at the
keypad.
Automatically scheduled or armed
state change that holds a door open
RTE or REX.
D# No Entry?
Default: No
Selection: Yes or No
Yes
Access Denied Events from this
door controller are sent to the
control panel for processing.
No
Access Denied Events from this
door controller are not sent to the
control panel for processing.
This program item determines if No Entry Events are
sent to the control panel for processing memory,
printing, and remote reporting.
A No Entry Event can be caused by:
Invalid or unknown user ID, interlock
or secured door, or incorrect authority
level
RTE or REX at an interlocked door.
RTE or REX at a door in the secured
mode.
RTE Events require D# Access Granted
to be programmed as Yes.
D# Exit Request?
Default: No
Selection: Yes or No
A Door REX Event from this door
controller is sent to the control panel
for processing.
Yes
A Door REX Event from this door
controller is not sent to the control
panel for processing.
No
This program item determines if REX Events are sent
to the control panel for processing memory, printing,
and remote reporting.