Bosch Appliances D9412GV2 Video Game Controller User Manual


 
D9412GV2/D7412GV2 | Program Entry Guide | 5.0 RADXSKED EN | 116
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
S## Function Code
Enter the function code you want this sked to execute.
Sked Function 12 is reserved and is not a valid entry.
The D5200 Programmer automatically retrieves the
appropriate sub-menu when the user enters a
function code. Refer to the following examples:
Example 1: When Function Code 1 (Arm Area) is
entered, the S## Area 1 [through 8] prompt
appears.
Example 2: When Function Code 3 (Bypass a
Point) is entered, the S## Point Number prompt
appears.
After you program the parameter choices associated
with the Sked function, press [EXIT GROUP] to
continue programming the sked for date, day of week,
time, and holiday.
Default: Blank
Selection: 1 to 11, 13 to 24, 28, 29
S## Area 1[through 8]
1
Arm Area: This function simulates
the Master Arm Delay keypad
function. Entries in the S## Area #
prompts define the area(s) this sked
arms. The sked can arm multiple
areas. If any point is faulted when the
sked executes, it is force armed
regardless of the A# FA Bypass Max
setting.
Default: No
Selections: Yes or No
Enable the sked to arm the
areas indicated with Yes.
Yes
No
Arm Area #.
Do not arm
Area #.
S## Area 1[through 8]
2
Disarm Area: This function emulates
the DISARM #? or DISARM ALL?
keypad function list options. Entries in
the S## Area # prompts define the
area(s) this sked disarms. The sked
can disarm multiple areas.
Default: No
Selection: Yes or No
Enable the sked to disarm the
areas indicated with Yes.
Yes
No
Disarm Area #.
Do not disarm
Area #.
S## Point Number
3
Bypass a Point: This function
emulates the Bypass Pt? keypad
function. The entry in the S## Point
Number prompt defines the point this
sked bypasses. The point can be
bypassed only if Bypassable is
programmed Yes in the point index
assigned to the point. The bypass is
reported if the Bypass Reports is
enabled by the point index settings
assigned to the point. The sked can
bypass one point.
Default: Blank
Selections: Blank, 1 to 127,
129 to 247 for D9412GV2,
1 to 75 for D7412GV2
Enter the number of the point
the sked bypasses.
Blank (0)
1 to 127,
129 to
247
No point is
bypassed
Point to bypass
S## Point Number
4
Unbypass a Point: This function
emulates the Unbypass Pt? keypad
function. The entry in the S## Point
Number prompt defines the point this
sked unbypasses. The sked can
unbypass one point.
Default: Blank
Selections: Blank, 1 to 127,
129 to 247 for D9412GV2,
1 to 75 for D7412GV2
Enter the number of the point
the sked unbypasses.
Blank (0)
1 to 127,
129 to
247
No point is
unbypassed.
Point to
unbypass.