D9412GV2/D7412GV2 | Program Entry Guide | 1.0 Introduction EN | 6
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
1.2 Product Handlers
Programming the 9000GV2 Series requires multiple product handlers. The availability of each handler is
indicated in
Table 3. Refer to the specific control panel’s release notes to determine the most current handler
versions.
Although the handlers shown in
Table 3 can be used to program any of the new control panels, not all of the
functions operate. For example, the RADXUSR1 Handler programs users 000 through 124. Even though the
handler allows you to program users 100 through 124, the D7412GV2 does not allow the activation of these
users.
Table 3: Product Handlers
Product
Handler
Compatible
Versions
Function D9412GV2 D7412GV2
GV2MAIN V1.03 and above
Covers Panel-Wide, Area, Keypad
Function List, User Interface, and
Relay programming modules.
9 9
RADXUSR1 V1.06 and above
Covers passcode and token
programming for users 000 through
124
(users 000 through 099 for the
D7412GV2).
9 9
RADXUSR2 V1.05 and above
Covers passcode and token
programming for Users 125 through
249.
9
N/A
RADXPNTS V1.08 and above
Covers Point Index and Point
Assignment programming for all
points.
9 9
RADXSKED V1.04 and above
Covers Open/Close Windows, User
Access Windows, Skeds, and Holiday
Index programming modules.
9 9
GV2AUX V1.03 and above
Covers SDI Automation, SDI RPS
Parameters, Enhanced
Communication Parameters, Route
Group Attempts, Miscellaneous, and
Cross Point Parameters.
9 9
RADXAXS V1.06 and above
Covers the programming parameters
for installed D9210B Door Controllers.
The program entry guide and program
record sheet for this handler come
with the D9210B Access Control
Module.
9 9