D9412GV2/D7412GV2 | Program Entry Guide | 8.0 SIA CP-01 Quick Reference EN | 150
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
8.0 SIA CP-01 Quick Reference
Table 45: Programming the Control Panels for SIA CP--01 Compliance
Prompt Name
Bosch Recommended Settings
for SIA CP-01 Compliance
Shipping Default References
Phone #
(Prefix backup phone number with
Call Waiting disable command)
{Blank} Page 11
Duress Type Option 3 0 (disabled) Page 35
Cancel Report Yes Yes Page 36
A# Exit Dly Time 45 sec to 255 sec 60 sec Page 38
A# Duress Enable Yes No Page 39
A# Exit Restart Yes or No Yes Page 49
A# Arm No Exit Yes or No Yes Page 49
A# Two Man Rule No No Page 47
A# Early Ambush No No Page 48
A# Exit Warning Yes Yes Page 49
A# Entry Warning Yes Yes Page 50
A# Burg Time
1
6 min to 90 min 6 min Page 42
A# Alarm Bell 1 to 128(64), A, B, C A (on-board alarm output) Page 79
CC# Entry Tone Yes or No Yes Page 54
CC# Exit Tone Yes or No Yes Page 54
CC# Abort Display Yes or No Yes Page 56
CC# Cancel Display Yes or No Yes Page 56
Master Arm Inst {Blank} {Blank} Page 61
Perim Instant {Blank} {Blank} Page 61
L## Send Duress [Blank] or E E
2
Page 75
L## Disarm [Blank] or E E
2
Page 67
L## Passcode Disarm [Blank] or E E
2
Page 75
P## Entry Delay 30 sec to 240 sec 30 sec Page 94
P## Alarm Abort Yes or No Yes
3
Page 102
Abort Window 15 sec to 45 sec 30 sec Page 140
Passcode Length 3 to 6 digits Disabled Page 141
Swinger Count 1 to 2 trips 1 trip Page 141
Remote Warning Yes Yes Page 141
Cross Point Time 5 to 255 sec 20 sec Page 143
P## Cross Point Yes or No No Page 100
1 The SIA allowed range is 1 min to 90 min.
2 L14 is the default duress user index.