Bosch Appliances D9412GV2 Video Game Controller User Manual


 
D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 55
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
CC# Close Door CC# Passcode Follows Scope
Default: No Default: Yes
Selection:
Yes or No
Selection:
Yes or No
Yes This keypad sounds a tone and
displays CLOSE DOOR #.
Yes Master Arming allows a user to
change the armed state of the areas
within the scope of this keypad. If the
areas in the scope are already at the
intended armed state, they remain in
that state.
No This keypad does not sound the
tone or activate the display.
Determines whether this keypad sounds an audible
tone and displays the CLOSE DOOR # warning on
the keypad. This occurs when the door is physically
held open past the shunt time and the extend time
has a value greater than zero for the door assigned to
this area in CC# Assign Door. Refer to the D9210B
Program Entry Guide (P/N: 32207).
If the area to which this keypad is
assigned is armed, entering a
valid pass code disarms this area
and all other areas assigned to
the scope of this keypad.
If the area to which this keypad is
assigned is disarmed, entering a
valid pass code arms this area
and all other areas assigned to
the scope of this keypad.
CC# EnhancCmdCtr
Default: No
Selection:
Yes or No
No Restricts the scope of the keypad to
the Area programmed in CC# Area
Assign for the purpose of executing
L## Passcode Arm and
L## Passcode Disarm only.
Yes This keypad is a D1260 Alpha V
Keypad.
No This keypad is not a D1260 Alpha V
Keypad.
Use this program to determine if this keypad follows
CC# Scope or if it only arms or disarms the area to
which it is assigned. The user must have authority
enabled in L## Passcode Arm and L## Passcode
Disarm.This feature does not affect the Function List
arming and disarming commands.
When a D1260 Alpha V Keypad is installed at this
keypad address, this item must be set to Yes.
Reboot the system to enable an Alpha V
keypad.
To reboot the system, close and open the
reset switch, labeled “S1 RESET,”
located in the upper right corner of the
control panel.
Tokens and cards disarm according to
this prompt. If this prompt is No, tokens
disarm only the Area to which the CC# is
assigned. The user must have disarming
rights for tokens and cards programmed
at the Disarm Level,. The user does not
need disarming and arming authority for
the keypad.
You can use this prompt for a group of
account-wide keypads that only arm the
area to which they are assigned, even if
the user has a pass code with arming
authority rights in all areas.