Bosch Appliances D9412GV2 Video Game Controller User Manual


 
D9412GV2/D7412GV2 | Program Entry Guide | 5.0 RADXSKED EN | 120
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
Default: Blank
Selection: 1 to 11, 13 to 24, 28, 29
S## Cmd Center 1[through 8]
Default: Blank
Ye
s
Watch tone sounds
at this keypad.
Sound Watch Tone at
Command Center (Keypad): This
function sounds the Watch Tone
at the keypad address
programmed in Parameter 1. The
Watch Tone sounds at all
keypads with the address
programmed. Press [ESC] to
silence the tone.
15
Watch tone does
not sound at this
keypad.
Selection: Yes or No
No
Enable the sked to beep the keypad
programmed Yes.
Sound Watch Tone defines the
keypad address where the Watch
Tone sounds. Enter the specific
address at the S## Cmd Center
prompt.
S## Access Ctl Level #
Default: No
Ye
s
Enable Access
Control Level #
Access Control Level On: This
function emulates the ACCESS
CMD LEVEL command that
determines whether a user’s
token or card level is ENABLED?,
allowing access granted rights.
This affects all doors that this
user is assigned to with this
specific authority level.
16
Do not enable
Access Control
Level #.
Selection: Yes or No
No
Activate a sked, which enables the
Access Level(s) 1 through 14 with
Yes.
The D9412GV2 supports eight doors; the D7412GV2 supports two doors.
To regulate a user’s access for certain doors, assign the user a different authority level # with the
same authority functions enabled. For example, a user can be assigned Authority Level 1 for
Door 1 and Authority Level 2 for the remaining doors. You can enable or disable Authority Level 1
for Door 1 without affecting his authority level for Doors 2 through 8).
Default: Blank
Selection: 1 to 11, 13 to 24, 28, 29
S## Access Ctl Level#
Default: No
Yes Turn off access for
level #.
Access Control Level Off:
This function emulates the
ACCESS CMD LEVEL
command that determines
whether a user’s token or card
level is disabled. This function
allows access to be turned off
for the levels programmed.
17
Do not turn off
access for level #.
Selection: Yes or No
No
The first parameter enables the sked
to turn off access for Levels 1 through
14.
S## Door 1 [through 8]
Default: No
Yes Unlock Door #.
Unlock Door: This function
emulates the UNLOCK?
12345678 keypad function for
unlocking a door.
18
Do not unlock
Door #.
Selection: Yes or No
No
Enable the sked to unlock the doors
programmed Yes.