D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 33
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
2.7.2 Log Threshold Reports
Log % Full
If communication with RPS is unsuccessful, or if no
phone number is programmed in RPS Ph, the control
panel generates Log Threshold and Bad Call to Ram.
This indicates the log is filling and the control panel
cannot download its events.
Default: Blank
Selection:
1 to 99, or Blank
This parameter determines how full the memory log
can be before initiating a call to RPS at the central
station. This allows the central station to call the
control panel and copy the memory log before
messages are overwritten.
If there is no RPS Ph programmed, the control panel
generates the Log Threshold and Bad Call to RPS
Events immediately. Bad Call to RPS Events are
logged only locally. If an RPS Ph is programmed, the
control panel makes multiple attempts to reach RPS
before sending the reports. Refer to the RPS Ph
prompt in Section
Blank disables the Log Threshold and Log Overflow
Events. These events are not entered in the log or
reported to the D6500 or D6600 or the local printer.
2.7.3 RPS Callback Reports for an
explanation of dialing characteristics.
The control panel continues to log events after the
Log Threshold Report is sent. When it reaches 100%
capacity (memory logger is full and previously stored
events are overwritten), the control panel generates a
local Log Overflow Event.
2.7.3 RPS Callback Reports
When dialing the RPS phone number, the control
panel makes two attempts to reach RPS. If the
control panel does not reach RPS on the first two
attempts, it waits 10 min then tries six more times
with a 10-min interval between each attempt. One
hour after the last failed attempt, the control panel
starts dialing the RPS phone number again. It makes
two more attempts then waits 10 min and tries six
more times with 10-min intervals between each
attempt before generating a Bad Call to RPS Report
and abandoning the effort.
The control panel does not call RPS again until it
downloads the log and the Log % Full percentage is
reached. These events are also sent to the control
panel’s event log and to the local printer(s) if
installed.
The Log Overflow Event is not sent to
the central station unless Expanded
Test Rpt is programmed Yes.
Remote Program Dialing Exception: When an RPS
phone number is programmed, the user can call RPS
by entering [COMMAND][4][3] and pressing the
[NEXT] key until CALLRPS? is displayed. Press
[ENTER]. Only one attempt is made to contact RPS.
Failure to program the RPS telephone
number results in a BAD CALL TO RPS
trouble event sent to the central station
when the log threshold is reached. Refer
RPS Passcode
to the prompt on page 35 for RPS Ph
information about programming the RPS
Default: 999999
telephone number.
Selection:
0 to 9, A to F
(six characters required)
Enter six characters. Do not use a space in the
passcode.
The control panel verifies the remote programming
software at the central station has valid access
before connecting using the RPS passcode.