Bosch Appliances D9412GV2 Video Game Controller User Manual


 
D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 74
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
L## Service Walk L## Default Text
Default: Refer to the program record sheet Default: Refer to the program record sheet
Selection: Blank or E Selection: Blank or E
Function
No.
Function Name
Alternate
Keystroke
Function Name
Function
No.
Alternate
Keystroke
33
Service Walk
Test
(Menu function
only)
34 Default Text [COMMAND][5][7]
Temporarily show the armed state of the area using
control panel default text, A# AREA # IS ON, A# NOT
READY, A# AREA # IS OFF, and A# ACCOUNT IS
ON.
Start a Service Walk Test for all 24-hour Interior or
Perimeter Controlled points in the control panel.
Points are not included in this test if:
Points are in an area that is already in a Walk
Test Mode.
L## Change Skeds
Default: Refer to the program record sheet
Points are assigned to an area that is not enabled
A# Area On.
Selection: Blank or E
Points are in an area that is Master or Perimeter
armed.
Function Name
Function
No.
Alternate
Keystroke
35 Change Skeds [COMMAND][5][2]
When a Service Walk Test is initiated, one person can
test all the points in the control panel without
assistance. The following features are provided with
the Service Test Mode:
Change skeds that can be edited.
Editing of skeds can be restricted by
Display indicates exactly how many points can be
tested.
programming S## Time Edit? to No.
Battery and bell tests do not occur during this
Walk Test.
L## Invisible Walk Test
The test ends when all points are tested or the
test times out after 20 min of inactivity.
Default: Refer to the program record sheet
Selection:
Blank, or E
Events print locally without alarm annunciation or
reporting to the central station receiver.
Function Name
Function
No.
Alternate
Keystroke
D1255 Keypad displays a sequential count and
the text for the point after each point is activated
and restored.
36 Invisible Walk Test (Menu function only)
Test all points that are programmed to be invisible
and that are within the scope of the keypad without
sending reports to the central station. Invisible points
must be programmed P## Invisible Pt as Yes. This
walk test mode can test 24-hour points and controlled
points.
The D1255 Keypad displays ALL PNTS TESTED.
If enabled in Routing, Service Start and Service
End are reported at the central station receiver for
the beginning and end of the test.
Point 128 and Point 248 appear as missing. This is
normal. These points are used for supervising the
Zonex 1 bus (Point 128) and Zonex 2 bus (Point 248).
If the Zonex bus has a fault, these points indicate a
short.
Invisible Test? allows the user with this L## to start
an invisible walk test for all 24-hour interior and
posterior controlled points in the area to which this
keypad is assigned. When an invisible test is started,
one person can test invisible points without
assistance.
This function allows viewing of extra points. Extra
points occur under two conditions: an extra point is
wired electrically to the Zonex bus with a blank P###
Point Index, or two Zonex devices exist for the same
Zonex address.
The following features are provided with the Invisible
Test Mode:
The display indicates exactly how many invisible
points are assigned to the area.
Battery and bell tests do not occur during this
walk test.