Bosch Appliances D9412GV2 Video Game Controller User Manual


 
D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 67
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
Custom Functions
Authority Level
C Function 128 [through 143]
Default: 1
Default: E
Selection:
1 to 14
Selection:
Blank, E, or P
Enter the number of the authority level you want to
program. Authority Level 15 (Service Passcode)
cannot be edited.
Function Name
Function
No.
Alternate
Keystroke
To determine the L## default values on
128 through
143
Enable Custom
Functions 128
through 143
(Menu function
only)
, refer to the User pages 67 through 76
When enabled, Custom Function determines if a pass
code is required when accessing a custom function
from the menu list. ENTER PASSCODE (or Enter
Passcode + Enter Key on the D1260) appears when
this function is pass-code protected. If a command
within the Custom Function is pass-code protected,
the keypad displays ENTER PASSCODE (or Enter
Passcode + Enter Key on the D1260) and waits for
the user to enter a valid pass code before proceeding
with the rest of the Custom Function. If a pass code is
not entered within 10 sec, the Custom Function times
out and the display returns to idle text.
2.11.4 Authority Level Selections
Use Section
2.11.4 Authority Level Selections on
page
67 to determine which Authority Level can
access keypad functions that are pass-code
protected. Selecting Enable items in the Authority
Level section is not necessary if the keypad function
is disabled or enabled. Each individual function has
two selections you can use for the authority level you
are programming.
Press the [SPACE] bar to scroll through the
selections. Press [ENTER] when the correct selection
appears in the display.
Table 28: Authority Level Selections
Authority
Level
Description
Blank
Disabled: This function is not
authorized for the user who is
assigned this authority level.
E
Enabled: This function is
authorized for the user who is
assigned this authority level.
Interface section for the GV2MAIN
Handler in the program record sheet.
L## Disarm
Default: Refer to the program record sheet
Selection: Blank or E
Function Name
Function
No.
1 Disarm
Use the disarming function to disarm areas that are
master armed or perimeter armed. If enabled, the
following disarming choices are available to the user
with this authority:
DISARM ALL: Disarms all areas within the CC#
Scope of the keypad being used by accessing
the Function Menu and the authority level of the
user performing the function.
DISARM AREA: Disarms only the displayed
area.
Many options are available for arming
and disarming. Selecting an option
depends on A# Area Type and CC#
Scope. Read the definitions of area type
in Section 2.9 Area Parameters on page
5 and CC# Scope in Section 2.10.1
Keypad (Command Center) Assignment
on page 51.