5.0 RADXSKED
5.1 Windows
Use this programming module to define the windows
for Opening and Closing and User Access.
5.1.1 Opening and Closing
Use these windows to set a schedule for disarming
and arming. The disarming and arming schedules
have several independent features:
Suppress normal Opening or Closing Reports
when A# Disable O/C in Windows is
programmed as Yes.
Generate a Fail to Open Report if the area is not
disarmed on schedule when A# Fail To Open is
programmed as Yes.
Provide a warning tone and a PLEASE CLOSE
NOW display at the keypad when it is time to arm
the area.
Generate a Fail to Close Report if the area is not
armed on schedule when A# Fail To Close is
programmed as Yes.
Automatically arm the area at the end of the
Closing Window when A# Auto Close is
programmed as Yes.
Opening and closing schedules can be set up
independently. For example, if you want to use
features provided only by Closing Windows, leave
times blank in the Opening Windows prompts and
program Closing Window times.
A worksheet is provided at the end of this section for
your convenience. Following the worksheet are
examples of programmming Opening and Closing
Windows for particular applications (refer to
Table 38
on page
112 through Table 42 on page 113).
About the program record sheet: A column labeled
Sked # is found in the program record sheet provided
with the control panel. The numbers in that column
appear in D6500 and D6600 reports and local printer
reports when the window Begin Time executes.
Window selections 1 through 8 correspond with odd-
numbered Skeds 41 through 55 for Open Window
and correspond with even numbered Skeds 42
through 56 for Close Window. For example, when the
Opening Window for Window 1 executes, a Sked 41
Executed event is generated. Refer to
Table 34.
Table 34: Window Selections
Selectio
n
Sked #
Windo
w
Sked #
Windo
w
1 41 Open 42 Close
2 43 Open 44 Close
3 45 Open 46 Close
4 47 Open 48 Close
5 49 Open 50 Close
6 51 Open 52 Close
7 53 Open 54 Close
8 55 Open 56 Close
Window
Default: 1
Selection: 1 to 8
Enter the window number you want to program.
W# Sunday
Default: No
Selection: Yes or No
Yes Activate this window on Sundays.
No
Do not activate this window on
Sundays.
This prompt and the next six day-of-the-week
prompts select the days of the week the Opening and
Closing windows are active.
Exceptions:
To prevent the windows from activating on certain
days of the year, program Xept Holiday as Yes, and
enable at least one Holiday Index. When Xept
Holiday is Yes, the window executes on the days of
the week programmed unless the Holiday Index
designates the date as a holiday.
If Opening and Closing Windows are only needed on
certain days of the year, do not program the windows
to execute on any days of the week. Instead,
program Xept Holiday as No and select a Holiday
Index with the days of the year you want the window