6.3 SDI Automation
6.0 GV2AUX
SDI automation defines the characteristics of a serial
interface module (SIM) when used with home or
business automation software. The SIM is a two-way
SDI to a serial communication module that allows the
control panels to send and receive information to and
from an external software program.
6.1 Introduction
The GV2AUX Handler is used primarily for
programming Enhanced Communication capabilities
for the 9000GV2 Series Control Panels.
“Enhanced communications” represents the ability to
provide new communication functions for the control
panels using the SDI bus including:
The SIM can be a D9133, DX4010i, or
DX4020 (configured to emulate serial
communication).
Routing control panel events to a network
interface module (NIM).
This automation protocol allows external software
programs to interact and perform functions such as:
A network interface module (NIM) can be
arming and disarming areas,
a D9133TTL-E or a DX4020.
changing user pass codes and names, and
turning relays on and off.
Communicating with remote programming
software (RPS) using a network interface module
(NIM).
The items described in this section allow some
simple configuration options. To receive the SIM
automation protocol; however, you must contact
Bosch Security Systems, Inc. Technical Support at
(888) 886-6189.
Communicating with a remote or local automatic
software package.
6.2 RPS and D5200 Handler
Requirements
Enable SDI Auto
In order to program the GV2AUX parameters for the
control panels, you must use RPS version 3.8 or
higher and a handler called GV2AUX. To add the
GV2AUX Handler to your D5200 Programmer, call
the Bosch Security Systems, Inc. Handler Update
System at
(800) 657-4584.
Default: No
Selection: Yes or No
Yes Enable Automation software.
No Disable Automation software.
Changing this item to Yes enables the automation
address (SDI Address 80).
This handler currently has six sections:
Baud Rate
SDI Automation
SDI RPS Parameters
Default: 9600
Enhanced Communications
300, 1200, 2400, 4800, 9600, 14.4
Selection:
K
SDI RPS/Enhanced Communication
Configuration
This item determines the baud rate between the
serial interface module (SIM) and the external
hardware connected to it. Since the SDI bus
communicates at 9600 baud, keep this prompt at
9600 baud. Pressing the [SPACE] bar on the D5200
toggles through the available options.
Miscellaneous
Cross Point Parameters
The handler required for these options is GV2AUX
version 1.0 and above. It is available on the Handler
Update System at Bosch Security Systems, Inc.