Bosch Appliances D9412GV2 Video Game Controller User Manual


 
D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 61
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
Master Arm Delay
Perim Instant
Default: P
Default: P
Selection:
Selection:
Blank, E, or P
Blank, E, or P
P Pass code: Required for all users
with Master Arm Delay enabled for
their authority level.
Function Name
Function
No.
Alternate
Keystroke
4
[COMMAND][2]
Perimeter Instant
Arm
E Enable: A user does not need a pass
code to use [COMMAND][1].
Instant arms all perimeter points with point response
that starts an instant alarm (refer to P## Pt Response
in Section
Blank Disable Master Arm Delay cannot be
accessed in the function menu or
started with a command even if this
function is enabled for the user’s
authority level.
4.2 Point Responses on page 92) in the
area where the keypad is assigned. Entry and exit
delays are not provided with this arming function.
This function causes a Perimeter Delay point to act as
a Perimeter Instant point.
For SIA CP-01 Compliance
Function Name
Function
No.
Alternate
Keystroke
2 Master Arm Delay [COMMAND][1]
Use this arming function to master arm disarmed
areas. If enabled, the following arming choices are
available to the user with this authority.
Mstr Arm Inst
Default: Blank
Selection:
Blank, E, or P
Function
No.
Function Name
Alternate
Keystroke
3
Master Arm
Instant
[COMMAND][1][1]
Use this arming function to master arm instant areas
that are disarmed. Entry and exit delays are not
provided with this arming function. This causes a
Perimeter and Interior Delay point to act as an Instant
point.
For SIA CP-01 Compliance
This feature is not allowed to be used
with SIA CP-01 compliant installations.
This feature is not allowed in SIA CP-01
compliant installations.
Perim Delay
Default: P
Selection:
Blank, E, or P
Function Name
Function
No.
Alternate
Keystroke
5
[COMMAND][3]
Perimeter Delay
Arm
Delay arms all Perimeter points in the area where the
keypad is assigned. Entry and exit delays are
provided with this Arming function. This function does
not cause a Perimeter Instant point to act as a Delay
point.
Watch Mode
Default: E
Selection:
Blank, E, or P
Function Name
Function
No.
Alternate
Keystroke
6 Watch Mode [COMMAND][6]
This function informs you when a perimeter point or
interior point that is programmed as P## Watch Point
is faulted while the area is disarmed. Interior points do
not emit a Watch Tone if the area is perimeter armed.
This function provides keypad audible or visual and
optional relay activation (refer to A # Watch Mode in
Section
2.13.1 Area Relays on page 79).