D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 20
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
Table 13: Test Reports
Report
Selection
s
Report
Description
R# S: Alarm
1
Yes, No Status Alarm
R# S: Trouble
1
Yes, No Status Trouble
R# S:
Supervised
2
Yes, No Status Supervised
R# Status
Report
Yes, No Status
R# S: Open
1
Yes, No Status Open
R# S: Close
1
Yes, No Status Close
R# Test Report Yes, No Test
R# S: Perim
Inst
1
Yes, No
Status Perimeter
Instant Arm
R# S: Perim
Delay
1
Yes, No
Status Perimeter
Delay Arm
R# S: Fire
Supv
2
Yes, No
Status Fire
Supervision
R# S: Fire
Alarm
3
Yes, No
Status Fire Alarm
Report
R# S: Fire Trbl
2
Yes, No Status Fire Trouble
R# S: Msng
Fire
2
Yes, No Status Fire Missing
R# S:
MsngBurgTr
2
Yes, No
Status Burg
Missing Trouble
R# S:
MsngBurgAl
2
Yes, No
Status Burg
Missing Alarm
R# S:
FireSpMsng
2
Yes, No
Status Fire
Supervision
Missing
R# S:
SuperMsng
2
Yes, No
Status Non-fire
Supervision
Missing
R# S:
DrLeftOpen
2
Yes, No
Status Door Left
Open
1
Information about this condition is sent with a Status
Report.
2
Information about this condition is sent as S: Trouble
Event with a Status Report.
3
Information about this condition is sent as S: Alarm
Event with a Status Report.
Diag Reports
Selecting Yes enables sending a report when the
event occurs. If the off-normal state of the events
indicated by footnote 1 in
Table 14 on page 20 still
exists, the events report when a Test Report is
enabled and Expanded Test Rpt is programmed
Yes. Refer to the Test Reports sub-prompt in
Section
2.3.8 Dialing Attempts on page 16.
Table 14: Diagnostic Reports
Report
Selection
s
Report
Description
R# SDI Dev Fail
1
Yes, No
SDI device
failure
R# SDI Dev Restl Yes, No
Restoral of SDI
device failure
R# Watchdog Rset Yes, No
Watchdog
Reset Event
R# ParaChksmFail Yes, No
Parameter
checksum
failure
R# Reboot Yes, No Reboot Event
R# Ph Line Fail
1
Yes, No
Failure of
phone line
R# Ph Line Rstl Yes, No
Restoral of
phone line
after failure
R# AC Fail
1, 2
Yes, No
Failure of AC
power to
control panel
R# AC Restorl
2
Yes, No
Restoral of AC
power to
control panel
after failure
R# Batt Missing
1, 2
Yes, No
Battery Missing
Detection
Event
R# Battery Low
1, 2
Yes, No
Low battery
power
R# Battery Rstl
2
Yes, No
Restoral of
battery power
to control panel
after Missing or
Low Event
R# Rt Comm Fail
1,
3
Yes, No
Failure to send
report to
specific route
R# Rt Comm Rstl Yes, No
Restoral of
communication
to specific
route after a
failure