Bosch Appliances D9412GV2 Video Game Controller User Manual


 
D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 73
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
L## Unbypass a Pt L## Move to Area
Default: Refer to the program record sheet Default: Refer to the program record sheet
Selection: Blank or E Selection: Blank or E
Function
No.
Function Name
Alternate
Keystroke
Function Name
Function
No.
Alternate
Keystroke
26 Unbypass a Point [COMMAND][0][0] 30 Move to Area [COMMAND][5][0]
Temporarily switch to a different area and perform
keypad functions related to that area.
Unbypass points with this authority level.
L## Reset Sensors
L## Display Rev
Default: Refer to the program record sheet
Default: Refer to the program record sheet
Selection: Blank or E
Selection: Blank or E
Function Name
Function
No.
Alternate
Keystroke
Function Name
Function
No.
Alternate
Keystroke
27 Reset Sensors [COMMAND][4][7]
32
[COMMAND][5][9]
Display Software
Revision
Reset sensors with this authority level.
L## Change Relay
Display the control panel model name and software
revision. For example:
Default: Refer to the program record sheet
9412GV2 REV ##.##
Selection: Blank or E
Function Name
Function
No.
Alternate
Keystroke
28 Change Relays [COMMAND][5][4]
Manually activate or reset a system relay.
Do not use the Chg Relays? function to
toggle relays reserved for special
functions. Special function relays are
Area and Panel Wide Relay functions as
well as relays assigned to CC# Entr Key
Rly?
L## Remote Program
Default: Refer to the program record sheet
Selection: Blank or E
Function Name
Function
No.
Alternate
Keystroke
29
[COMMAND][4][3]
Remote
Programming
Start a remote programming software (RPS) session
when the phone rings at the control panel.