Bosch Appliances D9412GV2 Video Game Controller User Manual


 
D9412GV2/D7412GV2 | Program Entry Guide | 1.0 Introduction EN | 7
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
1.3 Guide to Programming Options
To acquire an update for your D5200
Programmer, call the Bosch Security
Systems, Inc. Handler Update System at
(800) 657-4584. Make a separate phone
call for each handler.
Use an analog telephone line with the
D5200. The D5200 dials only pulses.
Refer to Section 10 Updating Handlers in
the D5200 Programmer Operation Manual
(P/N: 74-06176-000-B) for details on
updating handlers.
This guide is set up in a specific order. Related
program entries are grouped together in modules as
they appear in the specific product handlers. The
handler and the programming module are listed at the
top of each page to help you find specific
programming prompts.
This guide shows the programming options for each
product handler. Each option is listed with:
The Program Item Prompt: Each prompt is
shown as it appears in the D5200 Programmer
[refer to the D5200 Programmer Operation
Manual.(P/N: 74-06176-000)] or the Remote
Programming Software (RPS). Refer to the RPS
Installation and Operation Guide (P/N:
4998141259). For space considerations, some
prompts must be abbreviated in the Programmer
display. In these cases, the meaning of the
prompt is explained below the prompt
To connect the D5200 Programmer to the control
panel:
1. Close the reset switch, located in the upper
right corner of the control panel and labeled
S1 Reset, to place the D9412GV2 or
D7412GV2 Control Panel in the standby
mode.
2. Connect the Molex® connector at one end of
the cord to the connector labeled PROG on
the PCB and PROG CONN on the faceplate.
Program Entry Default Setting: Because
defaults are set for the typical installation,
programming each prompt might not be
necessary. Review the default entries in the
program record sheet shipped with the control
panel to determine which prompts must be
programmed.
To retrieve the current control panel configuration,
press the [RECV (COPY)] key on the D5200 at
the NEWRECORD prompt. Refer to the D5200
Programmer Operation Manual (P/N: 74-06176-
000) for detailed information.
Program Entry Selections: Only the selections
listed can be used for a particular program item.
To write new configuration information for the
control panel, press the [SEND (LOAD)] key at
the NEWRECORD prompt. Refer to the D5200
Programmer Operation Manual (P/N: 74-06176-
000) for detailed information.
Program Entry Description: Describes the
various entry selections. Read the descriptions
carefully to avoid improperly programmed
equipment.
To disconnect the D5200:
Custom Programming: Select custom
programming (Yes or No) to expand
programming modules within the D5200.
Programming Custom as Yes allows parameters
for special applications to be visible in the
programmer.
1. Disconnect the the Molex® connector.
2. Open the reset switch.
When the reset switch is opened, the
control panel reboots and resumes
normal operation within 5 to 25 sec.
1.4 Programming the Control Panel
with the D5200 Programmer
Table 4: Programming Error Displays
Display Description
INCOMPATIBLE
PANEL
You are connected to the
wrong control panel or using
the wrong handler. Check the
faceplate for the model
number and the handler title.
CHECK
CORD/RESET PIN
Check the cord and the reset
pin
Caution: Do not connect the D5200 to
the PROG connector without closing the
reset switch. Doing so causes SDI ##
TROUBLE and CALL FOR SERVICE to
display on the keypads. Door controllers
also activate, depending upon the SDI
failure DIP switch setting.