D9412GV2/D7412GV2 | Program Entry Guide | 6.0 GV2AUX EN | 141
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
Swinger Count
To meet UL requirements, the combined
Entry Delay time and Abort Window time
Default: 1
must not exceed 60 sec. For Entry Delay
time programming information, refer to
P## Entry Delay in the Point Responses
section of your control panel’s program
entry guide.
UL note: Maximum settings for
residential use:
Exit Delay – 120 sec
Entry Delay = 45 sec bell
Off-Premise Transmission = 60 sec
Maximum settings for commercial use:
Exit Delay – 120 sec no line security
Entry Delay = 60 sec bell
Off-Premise Transmission = 60 sec
The system must use both the bell and
off-premise transmission.
Selection:
1, 2, 3, or 4
1, 2 Number of fault or trouble bypasses
allowed per hour for SIA CP-01
compliance.
3 Optional fault count
4 Value used for backward
compatibility with previous control
panel operation.
When a point has P# Swinger Byps set to Yes, the
value set in Swinger Count determines the number
of times the point is faulted erroneously within an hour
before it is automatically bypassed.
For SIA CP-01 Compliance:
P## Swinger Byps can be Yes or No.
If P## Swinger Byps is Yes, Swinger Count must
be 1 or 2.
Passcode Length
Remote Warning
Default: 0
Selection:
0, 3, 4, 5, or 6
Default: Yes
Selection:
0 Sets a variable length for user
passcodes, allowing for backward
compatibility
Yes or No
Yes The system uses the Alarm Bell
output to annunciate the arming and
disarming of an area through remote
software, or a remote arming device
such as a key switch or key fob.
3, 4, 5,
or 6
Sets a fixed length to all user
passcodes.
During entry delay, the code is accepted when the
last digit is pressed to disarm the area.
No No remote warning occurs to
annunciate the arming and disarming
of an area through remote software,
or a remote arming device such as a
key switch or key fob.
For SIA CP-01 Compliance:
Passcode Length must be set to 3, 4, 5, or 6.
Upon remote arming, the output pulses on for 2 sec.
Upon remote disarming, the output pulses on, off, on,
off for 2 sec each.
For SIA CP-01 Compliance
Remote Warning must be set to Yes.