Bosch Appliances D9412GV2 Video Game Controller User Manual


 
D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 62
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
Perim Partial
View Memory
Default: P
Default: E
Selection:
Blank, E, or P
Selection:
Blank, E, or P
Function
No.
Function Name
Alternate
Keystroke
Function Name
Function
No.
Alternate
Keystroke
7
[COMMAND][8]
Perimeter Partial
Arm
9
[COMMAND][4][0]
View Event
Memory
Use this function to arm normal perimeter points and
force-bypass faulted perimeter points, regardless of
their P## Bypassable setting. When these force-
bypassed perimeter points return to normal, they
automatically return to service, even if P## FA
Returnable is set to No.
Use this function to view prior alarm, trouble, and
supervisory activity occurring since the last time the
system armed. Event memory is not cleared until the
area re-arms.
View Pt Status
Perimeter Partial arming has entry and exit delays.
Default: E
Perim Partial ignores the A# FA Bypass
Selection:
Blank, E, or P
Max entry in Section 2.9 Area
Function Name
Function
No.
Alternate
Keystroke
Parameters on page 36.
10 View Point Status
(Menu function
only)
Local Only Reporting: No Closing
Report is sent to the central station, but a
Use this function to view points assigned to the area
where the keypad is assigned. This function shows
point text and the electrical condition (normal, open,
short, and missing) of each point in the area.
Perimeter Delay Closing Event is
generated in the event log.
View Area Stat
Walk Test
Default: P
Default: E
Selection: Blank, E, or P
Selection:
Blank, E, or P
Function Name
Function
No.
Alternate
Keystroke
Function Name
Function
No.
Alternate
Keystroke
8 View Area Status
(Menu function
only)
11 Walk Test [COMMAND][4][4]
Use this function to view the armed status of all areas
within the scope of the keypad assigned to this area.
The armed states include A# AREA # IS OFF
(disarmed), A# AREA # IS ON (master delay armed),
ALL ON INSTANT (master instant armed), and AREA
# PERIM ON (perimeter instant armed or perimeter
delay armed). All area types, master, associate,
regular, and shared can be viewed using this function.
Use this function to test Controlled points in areas
within the keypad’s scope without sending reports to
the central station. 24-hour points cannot be tested
using this Walk Test Mode.
Fire Test
Default: P
Selection:
Blank, E, or P
Function Name
Function
No.
Alternate
Keystroke
12 Fire Test [COMMAND][5][8]
Use this function to test 24-hour points in areas within
the scope of the keypad where the function is
entered. Controlled points, P## Type 1, 2, 3, cannot
be tested using the Fire Walk Test Mode.