Bosch Appliances D9412GV2 Video Game Controller User Manual


 
D9412GV2/D7412GV2 | Program Entry Guide | 6.0 GV2AUX EN | 130
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
RPS IP Address 1 RPS Port Number
Default: 0 Default: 7700
Selection: 0 to 255 Selection: 1 to 65535
Enter the first three digits of the IP
address. Leading zeros are not
required.
0 to 255
This prompt specifies the destination port for
outgoing RPS session requests to the IP address
specified in RPS IP Address #.
6.4.2 Using an External Modem
This prompt and the next three prompts determine
the IP address for RPS.
Through the use of a standard, off-the-shelf modem
(capable of communicating at 9600 baud) and a
D9133DC connected directly to the control panel,
RPS can communicate with a D9412GV2 or
D7412GV2 at speeds of up to 9600 baud.
An IP address has four fields. Each field has a range
of 0 to 255. For example, an IP address is expressed
as 110.227.64.190. (Refer to
igure 7.) The D5200
programmer divides the IP Address into four
programmable fields. Contact your network
administrator to determine the IP address to which
the RPS computer is connected.
igure 7: RPS IP Address Prompts
Set RPS IP Address to 0 if Enable Ext
Modem is set to Yes.
RPS IP Address 2
Default: 0
Selection: 0 to 255
Refer to RPS IP Address 1.
RPS IP Address 3
Default: 0
Selection: 0 to 255
Refer to RPS IP Address 1.
RPS IP Address 4
Default: 0
Selection: 0 to 255
Refer to RPS IP Address 1.
Both the U.S.Robotics V.92 56 K Modem
(model No. 5686, includes V.92 and V.90
56 K standard technology) and the Best
Data Smart One V.92/V.44 56 K External
Data/Fax Modem (model # 56SX-92) are
recommended for use as external
modems (connected to the control panel)
based on compatibility testing by Bosch
Security Systems, Inc. Other modules
were not tested or were incompatible.
110.227.64.190
RPS IP Address 1
RPS IP Address 2
RPS IP Address 3
RPS IP Address 4
The seven prompts on page 134 help to configure the
requirements necessary to connect an external
modem to a D9412GV2 or D7412GV2 Control Panel
using a D9133DC. This configuration allows
communication with RPS at 9600 baud because data
is routed through the SDI bus.
Use a separate phone line if an external
modem is being connected to the control
panel by a D9133DC Direct Connect
Programming Module. If obtaining a
different phone line from the line used by
the control panel is impossible, ensure
that the control panel is wired in front of
any premises phone and the external
modem devices so that full line seizure is
maintained. Also, ensure that the
following items are programmed in
Section 2.7 RPS Parameters on page 32:
Answer Armed = Blank or 0
Answer Disarmed = Blank or 0
RPS Line Monitor = No
RPS Call Back = No
RPS Phone number = Blank