Bosch Appliances D9412GV2 Video Game Controller User Manual


 
D9412GV2/D7412GV2 | Program Entry Guide | 5.0 RADXSKED EN | 115
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
5.1.3 Holiday Indexes for User Group Windows
You can enable up to four Holiday Indexes to use
with User Group Windows. Enable at least one
Holiday Index if UW# Xept Holiday is programmed
as Yes for this user window, or if you want this
window to activate only on specific dates. Holidays
are programmed in Holiday Indexes. Refer to Section
5.3 Holiday Indexes on page 124 for programming
information.
UW# Xept Holiday
Default: No
Selection: Yes or No
Determine if the window is disabled on holidays, or is
active only on holidays. Use the instructions provided
in the W# Xept Holiday prompt on page 111.
UW# Holiday 1 [through 4]
Default: No
Selection: Yes or No
Yes
The selected holiday index can be
used by users in the User Group
window.
No
The selected holiday index does not
apply to users in this User Group.
5.2 Skeds
Use the Skeds module to program the control panel
to automatically execute functions that are otherwise
started by the end user at the keypad. Each sked can
be programmed to occur at a specific time on a
specific date or day of the week. Up to 40 Skeds can
be programmed.
A sked can be edited from the keypad if S## Time
Edit? is Yes. The date and time can be changed
using the Change Sked function.
Each sked number can be programmed with one of
24 functions for the S## Function Code. In addition
to the function, a choice must be made as to what is
affected by the function. For example, when choosing
Function 2 (Disarm Sked), the disarming is the
function and the selected areas are what is affected.
The functions and their associated parameters are
listed in the Sked Function Code Table in the
D9412GV/D7412GV2 Program Record Sheet
(P/N: F01U003635), and they are explained in detail
following the S## Function Code prompt on page
116.
Each sked can be programmed with up to four
Holiday Indexes. The Holiday Indexes can execute
the sked on the holidays as well as on the date or
day(s) of the week, or, they can prevent the sked
from executing on the holidays (refer to S## Xept
Holiday prompt in this section ).
Sked Number
Default: 1
Selection: 1 to 40
Enter the number of the sked you are programming.
S## TimeEdit
Default: Yes
Selection: Yes or No
Yes
The user can edit the time of this
sked from the keypad and
determines if this sked appears in
the CHG SKED display.
No
The user cannot edit the time of this
sked from the keypad and the sked
does not appear in the CHG SKED
display.
Select whether the user can edit the time of this sked
from the keypad.