W# Xept Holiday
Default: No
Selection: Yes or No
Yes
Do not activate this window on
holidays.
To use this selection, the window
must be programmed to activate on
at least one day of the week and a
Holiday Index must be enabled.
No
A holiday does not prevent this
window from activating.
You also use this selection if
Opening or Closing Windows are
needed only on certain days of the
year. Do not program the windows to
execute on any days of the week.
Instead, program Xept Holiday as
No, and select at least one Holiday
Index with the days of the year you
want the window to be active.
Determine if the window is disabled on holidays, or is
active only on holidays.
To prevent the windows from activating on certain
days of the year, program Xept Holiday as Yes, and
enable at least one Holiday Index. When Xept
Holiday is programmed as Yes, the window
executes on the days of the week programmed
unless the date is designated as a Holiday by the
Holiday Index(es) selected.
Holiday Indexes for O/C Windows
You can enable up to four Holiday Indexes for use
with Opening/Closing Windows. Enable at least one
Holiday Index if W# Xept Holiday is programmed as
Yes for this window, or if you want this window to
activate only on specific dates. Holidays are
programmed in Section
5.3 Holiday Indexes on page
124.
W# Holiday 1
Default: No
Selection: Yes or No
Yes
Use Holiday Index 1 with this
window.
No
Do not use Holiday Index 1 with this
window.
W# Holiday 2
Default: No
Selection: Yes or No
Yes Use Holiday Index 2 with this window.
No
Do not use Holiday Index 2 with this
window.
W# Holiday 3
Default: No
Selection: Yes or No
Yes Use Holiday Index 3 with this window.
No
Do not use Holiday Index 3 with this
window.
W# Holiday 4
Default: No
Selection: Yes or No
Yes Use Holiday Index 4 with this window.
No
Do not use Holiday Index 4 with this
window.
W# Area 1 [through 8]
Default: No
Selection: Yes or No
Yes
Activate the window in the area
number (#) specified.
No
Disable the window in the area
number (#) specified.
Eight separate program items determine whether a
particular window activates in each of the eight areas
of the control panel.