D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 43
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
Bell Test After Confirmation
A# Single Ring
In areas that send Opening and Closing Reports, the
Bell Test occurs after the control panel sends the
Closing Report and receives an acknowledgment
from the central station receiver. For proper operation
of the Bell Test after closing confirmation, the
following rules apply:
Default: No
Selection:
Yes or No
Yes One bell output per arming period.
After one alarm, alarms on any Non-
fire points in the same area cannot
restart the bell until the armed state
changes. An alarm on a different
point in same area restarts bell
output.
The control panel must send Opening and
Closing Reports to the central station.
Do not use restricted openings and closings or
Opening and Closing Windows.
Area Armed Confirmation
No Restart bell output with each alarm
event.
In areas that do not report opening and closing
activity, the alarm bell relay output for this area
activates for 2 sec after exit time expires.
Determines if an alarm from a non-fire point can
restart the alarm bell time with each Alarm Event, or
only start alarm output once per arming period.
Multiple Bell Tests occur: When more
than one area is armed at the same time
This does not silence the keypad alarm bell tone, or
prevent any reports. This feature does not affect Fire
points. Fire points restart bell time with each new
alarm.
(such as using the ARM ALL AREAS?
function), the bell rings for 2 sec with a
2 sec pause between each bell activation
if all areas have the same exit delay time
If an alarm occurs on a 24-hour point
while the area is disarmed, arming that
area with a key switch does not clear
the A# Single Ring flag.
programmed. Otherwise, the Bell Test
occurs as each area arms and it
completes its exit delay time.
When areas arm simultaneously and
report to the central station, the Bell
Silencing the bell resets A# Single
Ring.
Test occurs as the central station
receiver confirms each area.
A# Bell Test
2.9.5 Open/Close Options
Programming determines if Opening, All Normal
Closing, and Force Arm/Bypass Closing Events are
sent to the remote central station. Without remote
reports, all control panel and area arming (Closing
Events) and disarming (Opening Events) default to
local events.
Default: No
Selection:
Yes or No
Yes Start Bell Test.
No Do not start Bell Test.
Use this programming category to determine which
opening and closing supervision characteristics are
needed.
Provides alarm output from the relay programmed at
A# Alarm Bell after the Closing Report is confirmed
or the exit delay time expires.
There are three ways to generate reports from the
control panel. You can generate reports by account,
by area, or a combination of both.