Bosch Appliances D9412GV2 Video Game Controller User Manual


 
D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 75
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
The keypad shows point text when invisible points
are tested.
The test ends when all points are tested, or if the
test times out after 10 min of no activity.
Local event printing occurs without alarm
annunciation or reports sent to the central station
receiver.
The D1255 Keypad shows a sequential count and
text related to the point after each point is
activated and restored.
The keypad shows All PTS TESTED. An All
Points Tested Event is sent to the central station
receiver (if programmed) when the last point is
tested.
Walk Start and Walk End Reports are sent to the
central station receiver for the beginning and end
of the test (if programmed in phone routing).
Custom Functions
L## C Function 128 [through 143]
Default: Refer to the program record sheet
Selection: Blank or E
Function
No.
Function Name
Alternate
Keystroke
128 through
143
Enable Custom
Function 128
through 143
(Menu function
only)
Execute the desired Custom Function.
Report Levels
L## Force Arm
Default: Refer to the program record sheet
Selection: Blank or E
A user with this authority level can Force Arm.
L## Area O/C
Default: Refer to the program record sheet
Selection: Blank or E
Generates Opening and Closing Reports if the area
where this authority level is assigned sends Opening
and Closing Reports.
L## Restricted O/C
Default: Refer to the program record sheet
Selection: Blank or E
Generates an Opening Report if a bell is ringing or a
Closing Report when force or bypass arming. The
area where this authority level is assigned must be
programmed for restricted openings and closings
(refer to the A# Restrictd O/C prompt in Section
2.9.5
Open/Close Options on page 43.
L## Perimeter O/C
Default: Refer to the program record sheet
Selection: Blank or E
Generates Perimeter Opening and Closing Reports if
the area where this authority level is assigned sends
Perimeter Opening and Closing Reports. Refer to the
A# Perimeter O/C prompt on page 47 in Section
2.9.5 Open/Close Options.
L## Send Duress
Default: Refer to the program record sheet
Selection: Blank or E
Generates a Duress Report if the area where this
authority level is assigned sends duress. (Refer to the
A# Duress Enable prompt on page
39 in Section
2.9.5 Open/Close Options.)
L## Passcode Arm
Default: Refer to the program record sheet
Selection: Blank or E
Arm an area by entering a pass code and pressing
[ENTER].
L## Passcode Disarm
Default: Refer to the program record sheet
Selection: Blank or E
Disarm an area by entering a pass code and pressing
[ENTER].