Bosch Appliances D9412GV2 Video Game Controller User Manual


 
D9412GV2/D7412GV2 | Program Entry Guide | 5.0 RADXSKED EN | 108
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
W# Open Window Start
Default: 00: 00
Selection: HH:MM (hours and minutes)
Enter the time you want the control panel to start the
Opening Window. The window goes into effect at the
beginning of the minute.
Make time entries using a 24-hour clock.
For example:
Midnight is entered as 00:00
7:00 AM is entered as 07:00
2:45 PM is entered as 14:45
11:59 PM is entered as 23:59
This program item is one of three required to create
an Opening Window. To program an Opening
Window, Open Early Begin and Open Window Stop
must also be programmed. Refer to the W# Open
Early Begin prompt on page
107 for explanations of
report features.
W# Open Window Stop
Default: 00: 00
Selection: HH:MM (hours and minutes)
Enter the time you want the control panel to end the
Opening Window. The window stops at the end of the
minute.
Make time entries using a 24-hour clock.
For example:
Midnight is entered as 00:00
7:00 AM is entered as 07:00
2:45 PM is entered as 14:45
11:59 PM is entered as 23:59
This program item is one of three required to create
an Opening Window. To program an Opening
Window, Open Early Begin and Open Window Start
must also be programmed.
If the area is not disarmed by the time the Open
Window Stop time expires, the control panel
generates a Fail to Open Report if A# Fail to Open is
enabled in Area-Wide Parameters.
Opening Reports generated between the Open
Window Start time and Open Window Stop time can
be suppressed by programming A# Disable O/C in
Window as Yes. Refer to the W# Open Early Begin
prompt on page
107 for additional explanations of
report features.
Do not use a time of 23:59 as a window
stop time unless another window begins
on the next day at 00:00.
Fail to Open Reports are not sent for
windows that stop at 23:59.
Figure 5: Example Opening Window Timeline (using two Opening Windows on same day)
1
2
3
4
5
6
7
8
9
6 - Areas that are disarmed between 1 PM and 2
PM generate Early to Open Reports.
1 - Areas disarmed between midnight and 6 AM
generate Opening Reports.
7 - If the area is disarmed between 2 PM and 3
PM regular Opening Reports are generated. If
Disable O/C in Window is programmed Yes,
the Opening Report is not transmitted to the
central station.
2 - Areas disarmed between 6 AM and 7 AM
generate Early to Open Reports.
3 - If the area is disarmed between 7 AM and 8 AM
regular Opening Reports are generated. If
Disable O/C in Window is programmed Yes the
Opening Report is not sent to the central station.
8 - If the area is not disarmed by 3:01 PM, a Fail to
Open Event is generated if Fail to Open is
programmed Yes in Opening and Closing
Options.
4 - If the area is not disarmed by 8:01 AM, a Fail to
Open Event is generated if Fail to Open is
programmed Yes in Opening and Closing
Options.
9 - If the user disarms the area between 3:01 PM
and 11:59 PM, a Late to Open Event is
generated.
5 - If the user disarms the area between 8:01 AM
and 12:59, PM a Late to Open Event is
generated.