Bosch Appliances D9412GV2 Video Game Controller User Manual


 
D9412GV2/D7412GV2 | Program Entry Guide | 6.0 GV2AUX EN | 128
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
6.4 SDI RPS Parameters
6.4.1 User Interface Modifications for
COMMAND 43
Configure remote programming software (RPS)
parameters when communicating over a private local-
area network (LAN) or wide-area network (WAN). To
allow RPS to communicate with a control panel over
a LAN or WAN, an SDI-Ethernet two-way network
interface module (NIM) and an RPS (version 3.8 or
higher) are required. The computer on which RPS is
installed needs a network card. See your information
systems administrator for network requirements.
COMMAND 43 can communicate with RPS by a
network path.
Figure 6 on page 26 shows the
structure of COMMAND 43.
Pressing the [ESC] key during the display of
CONTACT RPS?, ANSWER NOW?, RPS VIA
PHONE?, or RPS VIA NETWORK? exits the user to
Idle Text.
Enable SDI RPS
This section allows you to:
Define the RPS parameters necessary to
communicate by an external modem that can be
connected to a D9133DC Direct Connect
Programming Module.
Default: Yes
Selection: Yes or No
Enable RPS sessions over the SDI
bus.
Yes
Provide for local programming by a DX4010i or
D9133DC Serial Interface Module.
Do not enable RPS sessions over
the SDI bus.
No
Provide remote programming by a Conettix
DX4020 or D9133TTL-E Ethernet Network
Interface Module.
Enable SDI RPS determines if the control panel
allows RPS communications over the SDI bus. This
item must be set to Yes if you plan to use the
external modem configuration, a private LAN or
WAN, or local RPS programming.
Provide enhanced route paths for event reporting
through a network using a DX4020 Network
Interface Module.
Although not listed in this section, RPS checks for the
RPS pass code (refer to Section
2.7 RPS Parameters
on page
32), Datalock Code, and control panel type
to determine if this RPS session should continue.
The RPS via Phone? prompt (Figure 6
on page 129), if selected, contacts RPS
by the control panel phone line and not
the external modem. Users cannot start
an RPS session by the external modem.
If you are using an external modem, RPS
sessions can be started only by
programming Answer Armed and Answer
Disarmed (to a value greater than 0) or
by setting RPS Line Monitor to Yes
(refer to Section 6.4.2 Using an External
Modem on page 130).
If the reset pin is in the locked position,
local RPS programming is allowed even
if this prompt is set to No.
When Enable SDI RPS is configured to
allow for local programming, Jumper 8 in
the SIM must be shorted or closed,
power must be removed and reapplied
after changing the address, and a
standard serial null-modem cable is
required.