Bosch Appliances D9412GV2 Video Game Controller User Manual


 
D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 71
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
General Functions
Table 29: L## Secure Door-Door Mode
Definitions
L## Chg Display
Default: Refer to the program record sheet
Door State Definition
Selection: Blank or E
Lock Door
Normal Door: When a door is in the
Lock Door state, one can initiate the
door sequence using Skeds, CYCLE
DOOR?, keypad functions, door
requests, and valid token or card
requests.
Function Name
Function
No.
Alternate
Keystroke
15 Change Display [COMMAND][4][9]
Change the display (bright display, dim display, and
time display) in the area where this keypad is
assigned.
No Access Allowed: When a door is
in the Secure Door state, no access
is allowed through the door until it is
returned to the Lock Door state. The
Secure Door state includes Sked and
keypad functions.
Secure
Door
L## Chg Time/Date
Default: Refer to the program record sheet
Selection: Blank or E
Free Access: When a door is in the Unlock
Door Unlocked Door state, the door is
already shunted and the door strike
does not prevent the door from
opening. In this state, the user does
not need to activate a door request or
present a valid token or card.
Function Name
Function
No.
Alternate
Keystroke
16
[COMMAND][4][5]
Change Time
and Date
Change the date and time for the control panel in this
area.
Cycle Door
Momentary Access: This is a
temporary Door Mode in which the
door initiates the door sequence as if
a valid token or card was read. This
state occurs using the keypad and
remote programming software (RPS).
A sked cannot activate this state.
L## Chg Passcode
Default: Refer to the program record sheet
Selection: Blank or E
Function Name
Function
No.
Alternate
Keystroke
17
[COMMAND][5][5]
Change
Passcodes
L## Access Ctl Lvl
Change a user pass code.
Default: Refer to the program record sheet
L## Add User
Selection: Blank or E
Default: Refer to the program record sheet
Function Name
Function
No.
Alternate
Keystroke
Selection: Blank or E
37
Access Control
Levels
(Menu function
only)
Function Name
Function
No.
Alternate
Keystroke
18 Add User [COMMAND][5][6]
Changing the Access Control Level in
Add or change users, add or change authority levels,
add or change tokens or cards.
any area affects all users and all doors
associated with that level for all areas.
9210 NOT READY appears if a door
controller is not assigned to the keypad
used to add or change tokens or cards.
Refer to CC# Assign Door in Section
2.10.1 Keypad (Command Center)
Assignment on page 53.