Bosch Appliances D9412GV2 Video Game Controller User Manual


 
D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 56
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
CC# Scroll Lock CC# Abort Display
Default: No Default: Yes
Selection:
Yes or No
Selection:
Yes or No
Yes Prevents the idle system status text
from scrolling automatically.
Requires user intervention to
advance.
Yes This keypad shows the Alarm
Aborted message for all aborted
alarms within its scope.
No This keypad does not show the
Alarm Aborted message for all
aborted alarms within its scope.
No Allows the idle system status text to
scroll automatically without user
intervention
This parameter enables or disables the ALARM NOT
SENT message when an alarm is aborted before
transmission occurs.
Use this parameter to enable a special non-scrolling
option for the idle system status display text on a
keypad. This keypad mode requires the user to press
the PREV or NEXT key on the keypad to unlock the
display and begin scrolling through the system status
displays.
For SIA CP-01 Compliance
CC# Abort Display can be set to Yes or No.
CC# Cancel Display
CC# Menu Key Lock
Default: Yes
Default: No
Selection:
Yes or No
Selection:
Yes or No
Yes This keypad shows the Cancel
Report Sent message for all canceled
alarms within its scope.
Yes If set to Yes, the user is prompted to
enter a pass code after pressing the
Menu key on the keypad. The items
programmed in the Menu List for this
specific keypad are filtered by the
user’s authority level. Only those
items in the menu list for which the
user has authority appear.
No This keypad does not show the
Cancel Report Sent message for all
canceled alarms within its scope.
This parameter enables or disables the CANCEL RPT
SENT display message when an alarm is canceled
after transmission occurs. To show this message,
Cancel Report must be set to Yes. Refer to
No If set to No, when the user presses
the Menu key, all items that are
programmed in the Menu List for the
Command Center Address (Keypad
Address) appear, regardless of the
user’s authority level.
Cancel
Report
on page 36.
For SIA CP-01 Compliance
CC# Cancel Display can be set to Yes or No.
Determines if the Menu Key, when pressed, requires
a pass code to access the functions.
If this parameter is set to Yes, users must
enter a pass code after pressing the
Menu key. When the pass code is
validated, only those functions for which
the user has authority appear in the list. If
a function in the Menu List is pass-code
protected (refer to Keypad Functions in
Section 2.11.2 User Interface on page)
the user does not need to enter the pass
code again.