Move to Area Default Text
Default: P Default: P
Selection:
Blank, E, or P
Selection:
Blank, E, or P
Function
No.
Function Name
Alternate
Keystroke
Function Name
Function
No.
Alternate
Keystroke
30 Move to Area [COMMAND][5][0] 34 Default Text [COMMAND][5][7]
Use this function to switch the keypad’s assignment
temporarily to a different area. This command can be
used to perform any function that can be performed
by a keypad assigned to the area in programming.
Determining the armed state of an area using the
programmed custom text might be difficult. Use this
function to switch temporarily to the control panel
default text, shown on the program record sheet.
Users are limited to performing functions enabled by
the authority level they have in the area to which the
keypad is moved. After 15 sec of no activity at the
keypad, the keypad reverts back to the originally
programmed area.
Change Skeds
Default: P
Selection:
Blank, E, or P
Display Rev
Function Name
Function
No.
Alternate
Keystroke
Default: E
35 Change Skeds [COMMAND][5][2]
Execute this panel-wide function from any keypad
assigned to an area where the user has authority.
Use this function to change the S## Time from the
keypad to make adjustments to Skeds.
Selection:
Blank, E, or P
Function Name
Function
No.
Alternate
Keystroke
32
[COMMAND][5][9]
Display Software
Revision
Invisible Walk Test
Use this function to show the control panel’s software
revision number in the keypad display.
Default: P
Selection:
Blank, E, or P
Service Walk
Function Name
Function
No.
Alternate
Keystroke
Default: P
Selection:
Blank, E, or P
36 Invisible Walk Test (Menu function only)
This function allows a user with the L## Invisible
Walk Test authority to test invisible interior or
perimeter controlled points that are within the scope
of the keypad, without sending reports to the central
station. Invisible points must have the P## Invisible
Pt function programmed Yes.
Function Name
Function
No.
Alternate
Keystroke
33
Service Walk
Test
(Menu function
only)
Use this function to Walk Test all 246 points in the
entire control panel regardless of the P## Type.
The Service Walk Test is available on the
D9412GV2 using the Service Menu
[9][9][ENT]. The D7412GV2 does not
include the Service Walk Test in the
Service Menu. In the D7412GV2, the
Service Walk Test function must be
enabled in the Function List to access the