NTCK16 Generic Central Office Trunk cards Page 797 of 894
Circuit Card Description and Installation
Therefore the following steps must be followed when the Generic XFCOT is
installed:
1 Define Loss Switching mode. Respond to the prompts in LD 97 as shown.
2 Define Loss Switching Class Of Service. Respond to the prompts in LD 14
as shown.
LD 97 – Defining Loss Switching mode.
Prompt Response Description
REQ: CHG
TYPE: SYSP IPE system parameters configuration
...
NATP YES Select North American transmission plan.
Note: The default to the NATP prompt is NO, and
therefore this prompt must always be checked during
installation.
LD 14 – Defining Loss Switching Class Of Service.
Prompt Response Description
REQ: CHG
TYPE: COT
XTRK XCOT
SIGL LOP
...
CLS
LOL
LOL= Long Line
Note: The XFCOT uses the CLS Long Line (LOL) and
Short Line (SHL) for Loss Switching purposes and that
the card and trunk type is different from the XUT.