Page 116 of 894 Option settings
553-3001-211 Standard 2.00 September 2004
NT6D80 Multi-purpose Serial Data Link card
Table 29
NT6D80 Multi-purpose Serial Data Link card
Port 0—SW4 Port 0—SW8
RS-232-D DTE or DCE*
RS-422-A DTE (terminal)
RS-422-A DCE (modem)
all off
all off
all on
all off
all on
all off
Port 1—SW3 Port 1—SW7
RS-232-D DTE or DCE*
RS-422-A DTE
RS-422-A DCE
all off
all off
all on
all off
all on
all off
Port 2—SW2 Port 2—SW6
RS-232-D DTE or DCE*
RS-422-A DTE
RS-422-A DCE
all off
all off
all on
all off
all on
all off
Port 3—SW1 Port 3—SW5
RS-232-D DTE or DCE*
RS-422-A DTE
RS-422-A DCE
all off
all off
all on
all off
all on
all off
* RS-232-D DTE and DCE modes are software configured. RS-422-A DTE and DEC modes are switch
configured.
Note: The device number for the MSDL card is configured in LD17 at the prompt DNUM. You
must also set the device number, using switches S9 and S10, on the MSDL card. S9 designates
ones and S10 designates tens. To set the device number as 14, for example, set S10 to 1 and
S9 to 4.