Page 140 of 894 Option settings
553-3001-211 Standard 2.00 September 2004
Table 48
QPC559, QPC560 double density
Application
Double density—Unit 0/1/2/3
H17/H3/A17/A3 switch
1 2 3 4 5 6
Outgoing ANI only:
loop pulsing off off off off off off
battery and ground pulsing off off off off on off
Other than outgoing ANI on off on off on off
Jumpers (QPC560) Units 0/1/2/3
600 ¾ resistive impedance connect pins 1 and 2
3-component complex impedance connect pins 2 and 3