Page 506 of 894 NT7D16 Data Access card
553-3001-211 Standard 2.00 September 2004
required. The defaults are bracketed, and may be issued by Carriage Return
(<CR>).
LD 11 – Configure Data Access card. (Part 1 of 3)
Prompt Response Description
REQ: NEW CHG MOV
COPY
Add, change, move or copy the unit
TYPE: R232
R422
RS-232-C unit
RS-422 unit
TN l s c u DAC data TN. The loop (LL) must be a superloop.
RNPG <CR> Ringing number pickup group (default to zero)
CLS
DTA
ADD
Class of Service allowed for the DAC.
Data Allowed
Digit Display Allowed
TOV (0) - 3 Timeout value, where:
0 = no timeout
1 = 15 minutes
2 = 30 minutes
3 = 60 minutes
OPE (NO) YES Operation parameter change
PAR (SPAC) ODD EVEN
MARK
SPAC = space parity
ODD = odd parity
EVEN = even parity
MARK = mark parity
DTR (OFF) ON DTR settings, where:
ON = forced DTR
OFF = dynamic DTR
This prompt appears only if TYPE = R232