Nortel Networks 553-3001-211 Video Gaming Accessories User Manual


 
Page 724 of 894 NTAK20 Clock Controller daughterboard
553-3001-211 Standard 2.00 September 2004
Note: The card is restricted to slots 1 through 3 in EMC- type cabinets
(such as NAK11Dx and NTAK11Fx cabinets). It will not work in slots 4
through 10 in these cabinets.
The NTAK20 clock controller card can support 1.5 Mb, 2.0 Mb, and 2.56 Mb
clock recovery rates.
Note: Clocking slips can occur between MG 1000S systems that are
clocked from different COs, if the COs are not synchronized. The slips
can degrade voice quality.
The clock controller circuitry synchronizes the system to an external
reference clock and generates and distributes the clock to the system. The
system can function either as a slave to an external clock or as a clocking
master. The NTAK20AD version of the clock controller meets the AT&T
Stratum 3 and Bell Canada Node Category D specifications. The
NTAK20BD version meets CCITT Stratum 4 specifications.
The NTAK20 card performs the following functions:
phase lock to a reference, generation of the 10.24 Mhz system clock, and
distribution of the clock to the CPU through the backplane
accept one primary and one secondary reference
primary-to-secondary switchover and auto-recovery
chatter prevention due to repeated switching
error-burst detection and correction, holdover, and free running
capabilities
communication with software
IMPORTANT!
Each MG 1000S that has a digital trunk must have a clock controller
clocked to an external reference clock.
If an IP Expansion multi-cabinet system is equipped with digital trunk
cards, it is mandatory that at least one trunk card is placed in the Main
cabinet.