Nortel Networks 553-3001-211 Video Gaming Accessories User Manual


 
NT7D16 Data Access card Page 479 of 894
Circuit Card Description and Installation
All S registers may be changed with the exception of S1, the Ring count. If
an attempt is made to change this parameter, the command is accepted but no
action is taken. The Ring count is the number of 6-second intervals that have
expired since an inbound call has been received. The current count may be
displayed through the Display S register command but cannot be altered After
a call is dropped, the Ring counter is set back to 0.
If, when using the display or alter commands, no register or value number is
input, the number 0 is used. For example, ATS? is equivalent to ATS0.
Allowable S registers Table 156 shows the supported S registers allowed by
the DAC. This table shows the register number, the range accepted (decimal
values shown), and a description of the register. Whenever a register value is
changed, the DAC checks for validity. If the value entered is not within the
allowed range, all processing ceases and no command processing following
the invalid entry is accepted. The DAC sends an ERROR result message.
Table 156
Allowable S registers (Part 1 of 2)
S register Range Range units Supported Description
S0 0–255 Rings Ye s Number of rings to answer a system
call (0 = manual answer)
S1 0–255 Rings Ye s Ring count for the current inbound
system call
S2 0–127 ASCII Ye s Off-line escape sequence character
S3 0–127 ASCII Ye s Input/output line terminating
character
S4 0–127 ASCII Ye s New line character for the output
line
S5 0–32,
127
ASCII Ye s Backspace character for input/
output lines
S6 2–255 Seconds No Wait time before blind dialing
S7 1–255 Seconds Ye s Timeout timer for far end answering