1 - 10
1 OVERVIEW
1.3 Restrictions by the software's version or serial number
There are restrictions in the function that can be used by the version of the operating
system software and programming software, or the serial number of Motion controller.
The combination of each version and a function is shown below.
Function
Operating system
software version
(Note-1), (Note-2)
Programming software version
(MELSOFT MT Works2)
Serial number of
Motion controller
Section of reference
Mark detection function 00H 1.06G
F********
(Note-3)
APPENDIX 1.10
Q170MCPU's internal I/F
(I/O signals (DI/DO))
00H 1.06G
F********
(Note-3)
Q170MCPU's internal I/F
(Manual pulse generator, Incremental
synchronous encoder)
00H 1.06G —
Section 2.5.1
MC protocol communication 00H 1.06G — APPENDIX 1.6
Incremental synchronous encoder
current value in real mode
00H — — APPENDIX 1.9
—: There is no restriction by the version.
(Note-1): SV13/SV22 is the completely same version.
(Note-2): The operating system software version can be confirmed in the operating system software (CD-ROM), installation display of
MT Developer2 or system monitor of GX Developer. (Refer to Section 2.2 or 2.3.)
(Note-3): Be sure to use the Motion controller since the first digit "F" of serial number. The serial number can be confirmed with the rated
plate, or on the front of Motion controller. (Refer to Section 2.2.)