Mitsubishi Electronics Q170MCPU Video Gaming Accessories User Manual


 
APP - 62
A
PPENDICES
(2) Transition conditional expressions
Processing time of transition conditional expressions
Classifications Symbol Instruction Operation expression
Processing time [µs]
Q170MCPU
M0
X100
1.0
4.5
PX0
2.0
(Note)
(None)
ON (Normally open
contact)
(Completion of condition)
U3E1\G10000.0 1.5
!M0
!X100
1.5
4.5
!PX0
2.5
(Note)
Bit device
status
!
OFF (Normally closed
contact)
(Completion of condition)
!U3E1\G10000.0 1.5
M0*M1
X100*X101
2.0
8.0
PX0*PX1
3.5
(Note)
* Logical AND
U3E1\G10000.0*U3E1\G10000.1 2.5
M0+M1 1.5
X100+X101 2.0
8.5
PX0+PX1
3.5
(Note)
Logical
operation
+ Logical OR
U3E1\G10000.0+U3E1\G10000.1 2.5
#0==#1
D800==D801
1.5
U3E1\G10000==U3E1\G10001 2.5
#0L==#2L
D800L==D802L
2.0
U3E1\G10000L==U3E1\G10002L
#0F==#4F
D800F==D804F
2.5
==
Equal to
(Completion of condition)
U3E1\G10000F==U3E1\G10004F 4.0
#0!=#1
D800!=D801
1.5
U3E1\G10000!=U3E1\G10001 2.5
#0L!=#2L
D800L!=D802L
1.5
U3E1\G10000L!=U3E1\G10002L 2.5
#0F!=#4F
D800F!=D804F
2.0
Comparison
operation
!=
Not equal to
(Completion of condition)
U3E1\G10000F!=U3E1\G10004F 3.5
(Note): The processing time that the I/O modules (PX/PY) are used with the Q170MCPU's internal I/F (DI/DO).