D9412GV3/D7412GV3 | Program Entry Guide | 2.0 Panel and Area Wide Parameters EN | 84
Bosch Security Systems, Inc. | 10/11 | F01U170807-02
2.1.6 Reporting and Logging
Phone # Format must be ModemIIIa
2
for the following reports sent to the central station. Regardless of the
reporting format, they log and print at the local printer as shown in Figure 4. Each sub-user is identified by the
master user’s three-digit number plus an extension of 0, 1, 2, or 3. These numbers are called Sub-user ID
Codes. shows all the users for User Group 122 as they would appear.
Figure 4: User Group 122 Example
Master User:
ID 122
.
CRD ID 122-0
Sub User -1: ID 122-1
CRD ID 122-1
Sub User -2: ID 122-2.
CRD ID 122-2
Sub User -3: ID 122-3.
CRD ID 122-3
2
1
1 - User passcode
2 - User token or card
In reporting systems using ModemIIIa
2
reporting format, all three digits of the User ID Code are
transmitted to the central station with appropriate reports. Central station automation computer
systems can accept only Zonex and Comex style User IDs. Refer to Point/User Flag in Section
2.1 Phone on page 12.