Events print locally without alarm annunciation or
reporting to the central station receiver.
D1255 Keypad displays a sequential count and
the text for the point after each point is activated
and restored.
The D1255 Keypad displays ALL PNTS
TESTED.
If enabled in Routing, Service Start and Service
End are reported at the central station receiver
for the beginning and end of the test.
Point 128 and Point 248 appear as missing. This is
normal. These points are used for supervising the
Zonex 1 bus (Point 128) and Zonex 2 bus (Point
248). If the Zonex bus has a fault, these points
indicate a short.
This function allows viewing of extra points. Extra
points occur under two conditions: an extra point is
wired electrically to the Zonex bus with P### Point
Index set to 0, or two Zonex devices exist for the
same Zonex address.
L## Default Text
Default: Refer to the program record sheet
Selection: - or E
Function
No.
Function Name
Alternate
Keystroke
34 Default Text [COMMAND][5][7]
Temporarily show the armed state of the area using
control panel default text, A# AREA # IS ON, A# NOT
READY, A# AREA # IS OFF, and A# ACCOUNT IS
ON.
L## Change Skeds
Default: Refer to the program record sheet
Selection: - or E
Function
No.
Function Name
Alternate
Keystroke
35 Change Skeds [COMMAND][5][2]
Change skeds that can be edited.
Editing of skeds can be restricted by
programming S## Time Edit? to No.
L## Invisible Walk Test
Default: Refer to the program record sheet
Selection:
-, or E
Function
No.
Function Name
Alternate
Keystroke
36 Invisible Walk Test (Menu function only)
Test all points that are programmed to be invisible
and that are within the scope of the keypad without
sending reports to the central station. Invisible points
must be programmed P## Invisible Point as Yes.
This walk test mode can test 24-hour points and
controlled points.
Invisible Test? allows the user with this L## to start
an invisible walk test for all 24-hour interior and
posterior controlled points in the area to which this
keypad is assigned. When an invisible test is started,
one person can test invisible points without
assistance.
The following features are provided with the Invisible
Test Mode:
The display indicates exactly how many invisible
points are assigned to the area.
Battery and bell tests do not occur during this
walk test.
The keypad shows point text when invisible
points are tested.
The test ends when all points are tested, or if the
test times out after 10 min of no activity.
Local event printing occurs without alarm
annunciation or reports sent to the central station
receiver.
The D1255 Keypad shows a sequential count
and text related to the point after each point is
activated and restored.
The keypad shows All PTS TESTED. An All
Points Tested Event is sent to the central station
receiver (if programmed) when the last point is
tested.
Walk Start and Walk End Reports are sent to the
central station receiver for the beginning and end
of the test (if programmed in phone routing).