P## Scope
Default: No Printer
Selection:
No Printer, Area, Account, Panel
Wide, Custom
Panel
Wide
Printer prints all designated events
that occur panel-wide. A panel-wide
printer can cross account boundaries.
Account Printer prints all designated events
that occur within any area with the
same account number in which this
printer is assigned.
Area Printer prints all designated events
that occur in the area to which this
printer is assigned.
Custom Printer prints all events occurring in
areas programmed Yes for this
prompt regardless of any boundary
restrictions.
No Printer No printer installed at this address. If
a printer is connected, data does not
print.
P## A1 [through A#] in Scope
Default: No
Selection:
Yes or No
Yes Include Area # Events in the scope of
this printer.
No Does not include Area # Events in
the scope of this printer.
Only available if P## Scope is programmed Custom.
This program item determines if events occurring in
an area print at this printer.
Refer to the report tables in Section 2.3
Routing on page 17 to identify the events
that print. Events programmed as No in
Routing still print at the local printer.
Individual events within the report group
cannot be suppressed for events printed
at the local printer.
P## Fire Events
Default: Refer to the program record sheet
Selection:
Yes or No
Yes All events in this group print at
assigned printer.
No No events in this group print at
assigned printer.
Use this prompt to determine whether these events
print at assigned printer.
P## Burglar Event
Default: Refer to the program record sheet
Selection:
Yes or No
P## Access Event
Default: Refer to the program record sheet
Selection:
Yes or No
P## User Event
Default: Refer to the program record sheet
Selection:
Yes or No
P## Test Event
Default: Refer to the program record sheet
Selection:
Yes or No
P## Diag Event
Default: Refer to the program record sheet
Selection:
Yes or No
P## Auto Functions Event
Default: Refer to the program record sheet
Selection:
Yes or No
P## RPS Event
Default: Refer to the program record sheet
Selection:
Yes or No
P## Relay Event
Default: Refer to the program record sheet
Selection:
Yes or No