Bosch Appliances d9412gv3 Video Game Controller User Manual


 
D9412GV3/D7412GV3 | Program Entry Guide | 4.0 Schedules (Skeds) EN | 112
Bosch Security Systems, Inc. | 10/11 | F01U170807-02
Table 36: Delivery Schedule*
Open Close
W# Day of Week
Early
Begin Start Stop
Early
Begin Start Stop
eXcept
On
Holiday
Holiday
Index
Area(s)
3
S M T W T F S
02 : 30 02 : 45 03 : 00 03 : 05 03: 15 03: 30 Yes No 1 2 3 4 1 2 3 4 5 6 7 8
00 : 00 01 : 00 Yes No 1 2 3 4 1 2 3 4 5 6 7 8
Program at least
one day Yes.
Day(s) of the week, but not on holidays Yes Select at
least one
index
Program at least
one area Yes.
* Monday and Wednesday, In between 2:45 AM and 3:00 AM. Out between 3:15 AM and 3:30 AM.
Another alternative for delivery schedules is to automatically bypass specific points using skeds.
Table 37: Monthly Auditor’s Schedule*
Open Close
W# Day of Week
Early
Begin
Start Stop
Early
Begin Start Stop
eXcept
On
Holiday
Holiday
Index
Area(s)
4
S M T W T F S
07 : 00 08 : 00 08 : 30 14 : 00 14: 30 17: 00 Yes No 1 2 3 4 1 2 3 4 5 6 7 8
All days must be
programmed No.
Only on holidays No Select at
least one
index
Program at least
one area Yes.
* Sunday, In between 8:00 AM and 8:30 AM. Out between 2:30 PM and 5:00 PM..
4.1.2 User Group Windows
In this section, you can create up to eight User Group
periods where the passcodes for the group chosen is
enabled. One user group can have multiple windows
assigned to it over a 24-hour period. Refer to the
U### User Group prompt in Section 2.1 Passcode or
Token Worksheet to assign individuals to a group.
When you assign a U### User Group to one of the
eight windows, all passcodes for the group are
enabled ONLY for the period between the Enable
Time and Disable Time for assigned User Windows
#.
If a user is not assigned to a U### User Group or
the number programmed for the user for U### User
Group is not assigned to a User Windows #, the
passcode for that user is enabled all the time.
User Group Windows do not affect the
users token or card access authority. To
enable/disable tokens, the Sked Function
Access Levels On/Off must be used.
User Windows #
Default: 1
Selection: 1 to 8
Enter the User Windows number you want to
program.
UW# User Group
Default: 1
Selection: 0 to 8
Enter the number programmed for the group of users
in the U### User Group prompt. This group has its
user passcodes enabled or disabled when this
window runs.
A User Group can be assigned to more
than one window in a 24-hour period, but
the windows must not overlap or exceed
the midnight boundary.