D9412GV3/D7412GV3 | Program Entry Guide | 2.0 Panel and Area Wide Parameters EN | 41
Bosch Security Systems, Inc. | 10/11 | F01U170807-02
2.8.2 Shared-Area Characteristics
Arming a Shared Area
A shared area arms automatically when all associate
areas are armed. As soon as the last associate area
is armed, the shared area automatically begins its
arming sequence. Passcode, key switch, sub-
controls, or RPS cannot arm shared areas. To
display faulted points at associate areas, the shared
and associate areas must have the same account
number.
Disarming a Shared Area
Shared areas automatically disarm when any
associate area in the control panel is disarmed.
Passcode, tokens, cards, key switch, sub-controls, or
RPS cannot disarm shared areas.
Shared Area Arming Sequence
When shared areas automatically begin to arm, the
arming is based on the A# Exit Dly Time is based on
the A# Exit Dly Time of the Shared Area.
Shared Area Not Ready
If a point is faulted in the shared area, CHK AREA
appears on the associate keypad that is arming the
last associate area. Associate area keypads can
show faults from shared areas as long as the shared
areas fall within the scope of the associate area.
Force Arming a Shared Area
When CHK AREA appears, press [ESC] to show
FORCE ARM at the associate keypad. Pressing
[ENTER] force arms the shared area if:
the user has authority to bypass points,
the point is bypassable, and
the number of faulted points does not exceed the
force arm maximum amount for the shared area.
Remember to include the shared area
in the associate area’s scope.
Viewing Shared Area Armed Status
View Area Status can be used from a keypad outside
of the shared area to view the shared area’s armed
state.
Silencing Sounders in the Shared Area
Silence shared area alarms and troubles from any
keypad.
To silence sounders, the user needs an authority
level assigned to the shared area. If the user also has
the authority to arm or disarm the area, then
ALREADY ARMED or ALREADY DISARMED
momentarily appears.
Access Control Readers Assigned to the Shared
Area
The shared area restarts the exit delay sequence
allowing a user to walk to an associate area and
disarm. If the token or card reader assigned to the
shared area includes any associate area in the D##
CC# Scope (in the access control section), both the
associate area and shared area disarms when the
token or card is presented. (Refer to Access Control
Readers Assigned to the Shared Area on page 41.)
Closing Reports for Shared Areas
If Closing Reports for shared areas are needed,
assign passcodes a valid authority level in the shared
area.
2.8.3 Bell Parameters
The D9412GV3 and the D7412GV3 have two main
types of annunciation: Fire Bell and Burg Bell. Both
Fire and Burg Bells share the same terminal
(Terminal 6) on the control panel as shipped from the
factory.
If a simultaneous Fire Bell and Burg Bell occur, the
Fire Bell takes precedence over the Burg Bell
regardless of which relay or terminal output they
share.
When the Fire and Burg Bells share the same output
and a Fire Bell occurs while the Burg Bell is ringing,
the Fire Bell pattern overrides the Burg Bell pattern.
At the end of the fire time, the burg pattern resumes.
When the Fire and Burg Bells share the same output
and a Burg Bell occurs while a Fire Bell sounds, the
control panel waits until the Fire time expires before
starting the Burg Bell.
Either a single bell (panel-wide) or a number of bells
(area-wide) can be used on the control panel. For
programming these applications, refer to Section
2.12.1 Area Relays on page 79.
When both Fire and Burg Bells occur simultaneously
and a user enters a valid passcode, a Fire Cancel
Report for the fire alarm and a Cancel Report for the
burg alarm is sent to the central station if Cancel
Reports is programmed Yes.