Bosch Appliances d9412gv3 Video Game Controller User Manual


 
D9412GV3/D7412GV3 | Program Entry Guide | 2.0 Panel and Area Wide Parameters EN | 58
Bosch Security Systems, Inc. | 10/11 | F01U170807-02
Custom Function
Default: 128
Selection:
128 to 143
Enter the Custom Function number you want to
program. You can program up to sixteen Custom
Functions, which are numbered 128 to 143.
CF### Text
Default: Refer to the program record sheet
Selection:
Sixteen alphanumeric characters.
See Section 2.9.2 Area Text on
page 56 for valid character entries.
Determines the menu text displayed at the keypad for
the custom function item. Use this text to represent
the functions performed by this menu item.
CF### Key Strokes
Table 22: CF### Key Strokes
Default:
Selection:
Refer to the program record sheet
Up to 32 characters: 0 to 9, A, B, C, D, E
Selection D1255 Key
D1255
Faceplate
Label
D1260 Key
0 to 9 0 to 9 0 to 9
A [COMMAND]
[COMMAND*]
B [PREV]
(previous)
NA
C [ESC]
(escape)
MENU NA
D [NEXT] NA
E [ENT] {enter} YES [#ENTER]
C1* NA (softkey 1)
C2* NA (softkey 2)
C3* NA (softkey 3)
C4* NA (softkey 4)
C5* NA (softkey 5)
C6* NA (softkey 6)
C7* NA (softkey 7)
C8* NA (softkey 8)
* Softkey selections are stored as two keystrokes.
The keystrokes simulate any sequence of keystrokes
the user can perform at a keypad. You can program
up to 32 keystrokes for each Custom Function.
Figure 3: Softkey Locations on the D1260
Keypad
1
2
ABC
3
DEF
4
GHI
5
JKL
6
MNO
7
PRS
8
TUV
9
WXY
0
COMMAND
*
ENTER
#
7
1
2
3
4
6
8
5
1 - Softkey 1 (C1)
2 - Softkey 2 (C2)
3 - Softkey 3 (C3)
4 - Softkey 4 (C4)
5 - Softkey 5 (C5)
6 - Softkey 6 (C6)
7 - Softkey 7 (C7)
8 - Softkey 8 (C8)
Programming Custom Function Keystrokes
Find the command you want to execute in the
User Interface section of the program record
sheet. Single digit commands must be
programmed with 9 as the second digit.
Table 23: CF### Custom Function Keystrokes
Command Keystroke
1 (Master arm area) A19
2 (Perimeter instant arm) A29
3 (Perimeter delay arm) A39
6 (Watch Mode) A69
7 (Special alert) A79
8 (Perimeter partial arm) A89
9 ( Special alert) A99
0 (Bypass a point) A09
When CF### Custom Function is programmed
with P, the corresponding custom function
number is passcode protected. The CF###
Custom Function prompt is under User
Interface > Cmd Center Functions. The passcode
protected custom function can be added to a
keypad’s function list by programming its number
in the Function List > M# Function prompt.