D9412GV3/D7412GV3 | Program Entry Guide | 2.0 Panel and Area Wide Parameters EN | 50
Bosch Security Systems, Inc. | 10/11 | F01U170807-02
A# Entry Warning
Default: Yes
Selection:
Yes or No
Yes Pulse the alarm output for the last 10
sec of the Entry Delay time.
No Do not pulse the Alarm Bell output
during the Entry Delay time.
When enabled, the Alarm Bell output pulses on and
off every 2 sec for the remaining 10 sec of the Entry
Delay time.
For SIA CP-01 Compliance
A# Entry Warning must be set to Yes.
2.9 Keypad (Command Center)
This programming module contains three
programming categories: Cmd Cntr Assignment,
Area Text, and Custom Function.
2.9.1 Keypad (Command Center) Assignment
This programming category assigns a keypad to an
area and determines if the keypad is supervised. The
keypads are connected to the control panel using a
two-wire serial data interface (SDI) bus.
This bus can support up to sixteen supervised
keypads, each with its own unique keypad address
(CC) and corresponding DIP switch address settings.
If the keypads are not supervised, you can install
multiple keypads with the same DIP switch address
setting for up to 32 unsupervised keypads.
Enhanced keypads (D1260 Series) and standard
keypads (D1255 Series) cannot share the same SDI
Address.
Cmd Center
DIP Switch Setting
SDI Address (CC#)
1 2 3 4 5 6
1 ON ON ON ON -- ON
2 OFF ON ON ON -- ON
3 ON OFF ON ON -- ON
4 OFF OFF ON ON -- ON
5 ON ON OFF ON -- ON
6 OFF ON OFF ON -- ON
7 ON OFF OFF ON -- ON
8 OFF OFF OFF ON -- ON
9 ON ON ON OFF -- ON
10 OFF ON ON OFF -- ON
11 ON OFF ON OFF -- ON
12 OFF OFF ON OFF -- ON
13 ON ON OFF OFF -- ON
14 OFF ON OFF OFF -- ON
15 ON OFF OFF OFF -- ON
16 OFF OFF OFF OFF -- ON
Enter the keypad (CC) number for the SDI address you are programming. This number corresponds to the DIP
switch address settings shown.
Switch 5: On=Encoding Tone On (default), Off=Encoding Tone Off
The D1255 can be addressed as 1 through 16. The D1260 can be addressed only as 1 – 8.