Bosch Appliances d9412gv3 Video Game Controller User Manual


 
D9412GV3/D7412GV3 | Program Entry Guide | 2.0 Panel and Area Wide Parameters EN | 59
Bosch Security Systems, Inc. | 10/11 | F01U170807-02
128 to 143 Enable Custom Function 128
through 143 (Menu Function only): This
function determines if a passcode is needed to
access a Custom Function from the menu list.
ENTER PASSCODE (or Enter Passcode + Enter
Key on the D1260) appears when this function is
passcode protected.
If a command within the Custom Function
is passcode protected, ENTER
PASSCODE appears at the keypad. The
user must enter a valid passcode before
proceeding with the rest of the Custom
Function. If a passcode is not entered
within 10 sec, the Custom Function times
out and the display returns to idle text.
Skeds cannot execute Custom Functions
that are passcode protected. The D720
LED keypad does not support Custom
Functions that are passcode protected.
Some functions cannot be entered directly
because they are nested inside a higher-level
function. To automatically execute these
functions, you must add the appropriate
keystrokes.
For example: The Change Display (COMMAND
49) function has three sub-functions: Bright
Display, Dim Display, and Date/Time Display.
- To turn up the display, enter:
[A][4][9][E]
- To dim the display, enter:
[A][4][9][D][E]
- To display time and date, enter:
[A][4][9][B][E]
Custom Functions can perform several tasks at
one time. For example:
To toggle relays 7, 8, and 9 in one Custom
Function enter:
[A] [5] [4] [7] [E] [E] [8] [E] [E] [9] [E] [E] [C]
To add a temporary passcode, enter:
[A] [5] [6] [3] [0] [E] [E] [9] [8] [7] [E] [E] [D] [E]
[1] [E] [1] [E] [1] [E] [1] [E] [1] [E] [1] [E] [1] [E]
[1] [E] [C]
This adds user 30, passcode 987 with
authority level 1 in all areas.
To delete the passcode, enter:
[A] [5] [3] [3] [0] [E] [E] [E] [C]
To program multiple-area Arming or Disarming
functions, use keystroke sequences including
COMMAND 50 (Move to Area) and
COMMAND 1.
Custom function cannot be used to
change time (such as Daylight Saving
Time). Use Skeds S## Function Codes
13 and 14 to adjust for Daylight Saving
Time (refer to S## Custom Function
prompt in Section 4.2 Schedules (Skeds)
on page 114.
Example 1
Execute the third function in a keypad menu function
list:
D1255 CDDE
D1260 C8C7C5
The custom functions in Example 1 are
not compatible between keypad types.
Example 2
Instant master Arm (CMD 11):
D1255 A11
D1260 A11
The custom functions in Example 2 are
compatible between keypad types.
The GV3 control panel series uses
separate keystrokes to program the
custom functions that accurately
represent the two separate user
interfaces, the D1255 and D1260
keypads.
Custom functions written for the D1255
that use the [PREV], [ESC], and [NEXT]
keys do not work on the D1260.
Custom function written for the D1260
that use the softkeys (located on the
sides of the keypad display) do not work
when executed from the D1255 keypad.
2.10 User Interface
Define which functions can be used by each of the
fourteen user authority levels. Each user can be
assigned the same or different authority level by
area. The user has rights in the area where the
keypad is assigned, based on the authority level
assigned to the user’s passcode for that area.
When the passcode is entered at the keypad, the
control panel checks the authority level. The control
panel executes the function only in areas where the
passcode has the authority to use the function.