2.10.1 Commands
Similar to command initiation used in other Bosch
Security Systems, Inc. products, the Commands
method provides continuity in the arming commands
across product lines and makes an easy transition for
dealers using other Bosch Security Systems, Inc.
products. With commands, the end user presses
[COMMAND] and then the numeral of the command
to initiate. For example, [COMMAND][2] arms the
perimeter of the area. Some prompts can be
accessed only from a menu. These prompts are
indicated by (Menu Function only). To access these
functions, press [MENU], enter the function number,
and use the [PREV] and [NEXT] keys to scroll
through the choices.
The D9412GV3/D7412GV3 Program Record Sheet
(P/N: F01U170809) lists the commands available
with the system. Command numbers are shown in
the column labeled Command. If a particular function
does not have a command number, it can be
accessed only through the Function List.
If you plan to use only commands to operate the
system, and to arm and disarm by entering a
passcode, you do not need to program Custom
Function or Function List.
2.10.2 Command Authorization
Programming choices in this section determine if
keypad functions are disabled (-), enabled (E), or
passcode (P) restricted.
Table 24: Keypad Programming Choices
Selection Description
-
Disable the function panel-wide.
The keypad shows NO
AUTHORITY if you access the
function using a command or the
Function List.
E
Enable the function panel-wide.
The function can be executed
without entering a passcode.
P
Passcode required. When the
passcode is entered at the
keypad, the control panel checks
the user’s authority level. Refer to
Section 2.10.6 Authority Level
Selections on page 66.
Refer to Section 2.10.6 Authority Level
Selections on page 66 for a detailed
description of the functions on the
following pages. These parameters
determine only if the authority level
functions are passcode protected.
Master Arm Delay
Default: P
Selection:
-, E, or P
P Passcode: Required for all users with
Master Arm Delay enabled for their
authority level.
E Enable: A user does not need a
passcode to use [COMMAND][1].
- Disable Master Arm Delay cannot be
accessed in the function menu or
started with a command even if this
function is enabled for the user’s
authority level.
Function
No.
Function Name
Alternate
Keystroke
2 Master Arm Delay [COMMAND][1]
Use this arming function to master arm disarmed
areas. If enabled, the following arming choices are
available to the user with this authority.
Master Arm Instant
Default: - (Disabled)
Selection:
-, E, or P
Function
No.
Function Name
Alternate
Keystroke
3
Master Arm
Instant
[COMMAND][1][1]
Use this arming function to master arm instant areas
that are disarmed. Entry and exit delays are not
provided with this arming function. This causes a
Perimeter and Interior Delay point to act as an Instant
point.
For SIA CP-01 Compliance
This feature is not allowed to be used
with SIA CP-01 compliant installations.
Perimeter Instant
Default: - (Disabled)
Selection:
-, E, or P
Function
No.
Function Name
Alternate
Keystroke
4
Perimeter Instant
Arm
[COMMAND][2]