BURN_BIOS Although not recommended, setting this flag’s value to NO will
prevent BIOS upgrade.
Default: YES.
CAC_ENABLE When set to YES, enables the Call Admission Control
implementation in the Collaboration Server.
Default: NO (CAC is disabled)
CASCADE_LINK_PLAY_TO
NE_ON_CONNECTION
When set to YES, the Collaboration Server plays a tone when
a cascading link between conferences is established. The
tone is played in both conferences.
This tone is not played when the cascading link disconnects
from the conferences.
The tone used to notify that the cascading link connection has
been established cannot be customized.
Default value: NO.
The tone volume is controlled by the same flag as the IVR
messages and tones: IVR_MESSAGE_VOLUME.
CELL_IND_LOCATION Change the location of the display of Network Quality
Indicators displayed in the cells of the conference Video
Layout.
Default: TOP_RIGHT
Range:
BOTTOM_LEFT
BOTTOM_RIGHT
TOP_LEFT
TOP_RIGHT
CFG_KEY_ENABLE_FLOW_
CONTROL_REINVITE
Used to enable or disable sending a re-INVITE to endpoints to
adjust their data rate. When set to YES, re-INVITE is used for
endpoints that do not support flow control in SIP using either
the Information or RTCP Feedback mechanisms.
Default: NO.
CONF_GATHERING_DURAT
ION_SECONDS
The value of this System Flag sets the duration of the
Gathering Phase in seconds. The Gathering Phase duration
of the conference is measured from the scheduled start time
of the conference.
Range: 0 - 3600
Default: 180
For more information see "Video Preview (AVC Only
Participants)” on page 3-20.
Table 20-2 Manually Added System Flags – MCMS_PARAMETERS (Continued)