AND, ANI
- 45 -
Program example
(1) Program used after LD, LDI, AND or ANI, etc.
Coding
No. of
steps
Com-
mand
Device
10 LD X3
11 AND M6
12 LDI X4
13 ANI M7
14 ORB
15 ANI M9
16 OUT Y33
17 LD X5
18 LD M8
19 OR M9
20 ANB
21 ANI M11
22 OUT Y34
X4
Y34
X3 Y33
10
17
M11M8
M9
X5
M7
M6
M9
ORB
ANB
23
(2) Program used to connect contact in parallel with coil.
Coding
No. of
steps
Com-
mand
Device
93 LD X5
94 OUT Y35
95 AND X8
96 OUT Y36
97 ANI X9
98 OUT Y37
X9
X5
Y35
93
X8
Y36
Y37
99