9. Exclusive Commands
- 205 -
(10) Tool data write
Instead of setting tool No. through the setting and display unit, the tool No. is entered to each
magazine No. set through PLC program.
R500
R501
R540
R2965
R3000
R3001
:
:
:
:
R3009
R3010
540
545
2
1000 (0)
1001 (1)
1002 (2)
1003 (3)
1008 (8)
1009 (9)
Register No. having magazine No. to which data is written
Magazine No. to which data is written
Pointer
R502
R545
1234
Data to be written
Data "1234" is written to magazine No. .
:
:
:
Register No. where data to be written is stored
9
10
MG.1
2
4
5
6
7
8
8
9
MG.0
1
2
4
5
6
7
3
3
Magazine starts from "0".
Magazine starts from "1".
----
:
3
3
1234 (4)
1234 (5)
(6)
(7)
R500
S.ATC
K10
ACT
M10
R2960
(Note) When pointer is not used, R2965 should be
set to "zero".
Ex.) MOV K0 R2965